Fully automated immunoassay for quantitative determination of FXIII.

نویسندگان

  • A Kappel
  • S Stephan
  • C Duwe
  • L Pechmann
  • H Althaus
  • M Ehm
  • B Fischer
  • M Hahn
  • H Schwarz
  • F Vitzthum
چکیده

UNLABELLED Coagulation factor XIII (FXIII) is essential for clot stabilization. Deficiency of FXIII is associated with a risk of bleeding and impaired wound healing. Substitution therapy with FXIII remedies for patients with low plasma levels of FXIII requires diagnostic quantification of the factor before and during therapy. Here, we describe a prototype of a preliminary research immunoassay for quantification of FXIII antigen on automated coagulation instruments. The prototype assay is based on a monoclonal antibody (mAb) directed against FXIII A chain, whereas the mAbs are coupled to latex particles. FXIII in a plasma specimen causes agglutination of the latex particles, which can be quantified turbidimetrically. Performance data of the assay prototype processed on BCS® XP and Sysmex® CA-1500 instruments demonstrate a good correlation to the Berichrom® factor XIII activity assay1 from Siemens Healthcare Diagnostics (r = 0.94). RESULTS Comparability of instruments was excellent (r = 0.98). Coefficients of variation of total imprecision measurements ranged from 2.2 to 3.4%. Linearity was excellent over the range tested (12-121% FXIII). Analytical sensitivity was 0.51% FXIII on BCS XP and 0.44% FXIII on Sysmex CA-1500, respectively. No interference (>10% bias) was observed with haemoglobin (up to 400 mg/dl), cholesterol (up to 300 mg/dl), bilirubin (up to 60 mg/dl) or triglycerides (up to 3000 mg/dl). CONCLUSION The preliminary research assay prototype has the potential for excellent analytical sensitivity, precision, and dynamic range suitable to measure reliably FXIII antigen levels in human plasma.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical evaluation of a fully automated immunoassay for faecal calprotectin in a paediatric setting

Introduction Faecal calprotectin (FC) is a routinely used marker for identifying and monitoring children with inflammatory bowel disease (IBD). This non-invasive test is useful for screening children with gastrointestinal symptoms to avoid unnecessary invasive procedures. In this study, we validated for the first time the performance of a fully automated particle-enhanced turbidimetric immunoas...

متن کامل

A modified, optimized kinetic photometric assay for the determination of blood coagulation factor XIII activity in plasma.

BACKGROUND Blood coagulation factor XIII (FXIII) is a zymogen that is transformed into an active transglutaminase by thrombin and Ca(2+). FXIII plays an essential role in fibrin stabilization and in the protection of fibrin from proteolytic degradation. No convenient method has been available for the measurement of FXIII activity in plasma. The aim of the present study was to improve and optimi...

متن کامل

Measurement of factor XIII activity in plasma.

Coagulation factor XIII (FXIII) is converted by thrombin and Ca(2+) into an active transglutaminase (FXIIIa) in the final phase of coagulation cascade. Its main function is the mechanical stabilization of fibrin clot and its protection from fibrinolysis by cross-linking of fibrin chains and α(2)-plasmin inhibitor to fibrin. In non-substituted patients FXIII deficiency is a severe hemorrhagic di...

متن کامل

Detection of virus-specific intrathecally synthesised immunoglobulin G with a fully automated enzyme immunoassay system

BACKGROUND The determination of virus-specific immunoglobulin G (IgG) antibodies in cerebrospinal fluid (CSF) is useful for the diagnosis of virus associated diseases of the central nervous system (CNS) and for the detection of a polyspecific intrathecal immune response in patients with multiple sclerosis. Quantification of virus-specific IgG in the CSF is frequently performed by calculation of...

متن کامل

Automated Determination of Serum 1-Antitrypsin by Antitryptic Activity Measurement

BACKGROUND: 1-Antitrypsin (A1AT) deficiency is currently detectable by protein immunoassay, phenotyping, and genotyping of the S and Z mutations, but no fully automated method for standard biochemical analyzers is yet available. Here, we present a method that measures the antitryptic activity in serum. This method is rapid, automated, and allows the easy evaluation of a large cohort of patients.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Hamostaseologie

دوره 31 2  شماره 

صفحات  -

تاریخ انتشار 2011