Non-invasive Predictors of Human Cortical Bone Mechanical Properties: T2-Discriminated 1H NMR Compared with High Resolution X-ray

نویسندگان

  • R. Adam Horch
  • Daniel F. Gochberg
  • Jeffry S. Nyman
  • Mark D. Does
چکیده

Recent advancements in magnetic resonance imaging (MRI) have enabled clinical imaging of human cortical bone, providing a potentially powerful new means for assessing bone health with molecular-scale sensitivities unavailable to conventional X-ray-based diagnostics. To this end, (1)H nuclear magnetic resonance (NMR) and high-resolution X-ray signals from human cortical bone samples were correlated with mechanical properties of bone. Results showed that (1)H NMR signals were better predictors of yield stress, peak stress, and pre-yield toughness than were the X-ray derived signals. These (1)H NMR signals can, in principle, be extracted from clinical MRI, thus offering the potential for improved clinical assessment of fracture risk.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MRI Measures of Cortical Bone Water Concentration: Dependence on Age and Pore Volume Fraction

Introduction: Age-related increase in cortical bone porosity is a major cause of the impaired strength of osteoporotic cortical bone. The majority of these pores, however, are below the resolution limit achievable in vivo. Water H NMR signal in bone at 3T results from two compartments: long T2 (T2 ≥ 1 ms), corresponding to free water in pores (‘pore water’); and short T2 (T2 ~ 300-400 μs), corr...

متن کامل

On study of X-ray absorption and properties of dispersion of W, MoS2 and B4C particles in high density polyethylene

Shielding radiation from both x-rays and gamma-rays is important for personnel in medical fields e.g. interventional radiology, nuclear power stations, and other inspection facilities where radiation is involved. Lead is known for its effective shielding property against these high energy radiations, however heaviness and toxicity are its main drawback. In this study effectiveness of non-lead p...

متن کامل

Microarchitecture, the key to bone quality.

Bone has the ability to adapt its shape and size in response to mechanical loads via a process known as modelling in which bones are shaped or reshaped by the independent action of osteoblasts and osteoclasts. Remodelling is a process that maintains mechanical integrity of the skeleton, allowing it to selectively repair and replace damaged bone. During adulthood, bone remodelling is the dominan...

متن کامل

Ultrashort echo time magnetization transfer (UTE-MT) imaging of cortical bone.

Magnetization transfer (MT) imaging is one way to indirectly assess pools of protons with fast transverse relaxation. However, conventional MT imaging sequences are not applicable to short T2 tissues such as cortical bone. Ultrashort echo time (UTE) sequences with TE values as low as 8 µs can detect signals from different water components in cortical bone. In this study we aim to evaluate two-d...

متن کامل

High-Resolution Peripheral Quantitative Computed Tomography Can Assess Microstructural and Mechanical Properties of Human Distal Tibial Bone

High-resolution peripheral quantitative computed tomography (HR-pQCT) is a newly developed in vivo clinical imaging modality. It can assess the 3D microstructure of cortical and trabecular bone at the distal radius and tibia and is suitable as an input for microstructural finite element (microFE) analysis to evaluate bone's mechanical competence. In order for microstructural and image-based mic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011