Biodosimetry estimation using the ratio of the longest:shortest length in the premature chromosome condensation (PCC) method applying autocapture and automatic image analysis

نویسندگان

  • Jorge E. González
  • Ivonne Romero
  • Eric Gregoire
  • Cécile Martin
  • Ana I. Lamadrid
  • Philippe Voisin
  • Joan-Francesc Barquinero
  • Omar GarcÍa
چکیده

The combination of automatic image acquisition and automatic image analysis of premature chromosome condensation (PCC) spreads was tested as a rapid biodosimeter protocol. Human peripheral lymphocytes were irradiated with (60)Co gamma rays in a single dose of between 1 and 20 Gy, stimulated with phytohaemaglutinin and incubated for 48 h, division blocked with Colcemid, and PCC-induced by Calyculin A. Images of chromosome spreads were captured and analysed automatically by combining the Metafer 4 and CellProfiler platforms. Automatic measurement of chromosome lengths allows the calculation of the length ratio (LR) of the longest and the shortest piece that can be used for dose estimation since this ratio is correlated with ionizing radiation dose. The LR of the longest and the shortest chromosome pieces showed the best goodness-of-fit to a linear model in the dose interval tested. The application of the automatic analysis increases the potential use of the PCC method for triage in the event of massive radiation causalities.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Induction of premature chromosome condensation (PCC) by calyculin A for biodosimetry

Background: Premature chromosome condensation (PCC) is a method for interphase chromosome analysis in biodosimetry. This study was performed to verify the usefulness of PCC induced by calyculin A in human peripheral blood lymphocytes (pbl) for biological dosimetry and possible construction of dose-response curve. Materials and Methods: Peripheral blood was obtained from a healthy donor and expo...

متن کامل

Biological Dose Assessment by Chemical Induction of Premature Chromosome Condensation

Dose assessment of radiation victims is a key element in medical management of radiation accidents. At high radiation doses (> 6 Gy), dicentric assay lose its efficiency and premature chromosome condensation (PCC) assay was proposed to overcome the restrictions of dicentric assay. It was shown that PCC ring is more suitable and simpler than dicentric for biodosimetry in high radiation doses. In...

متن کامل

Construction of a dose – response curve by induction of premature chromosome condensation for biological dosimetry

Premature Chromosome Condensation (PCC) appears to have a possible utility for biological dosimetry purposes. The PCC technique may be adapted for cases of suspicion of overexposure where sampling is performed at least one day after an accident. For this purpose, human blood samples were exposed in vitro to 60Co up to 10 Gy and the PCC technique was performed immediately after irradiation. Anal...

متن کامل

Triage biodosimetry using centromeric/telomeric PNA probes and Giemsa staining to score dicentrics or excess fragments in non-stimulated lymphocyte prematurely condensed chromosomes.

The frequency of dicentric chromosomes in human peripheral blood lymphocytes at metaphase is considered as the "gold-standard" method for biological dosimetry and, presently, it is the most widely used for dose assessment. Yet, it needs lymphocyte stimulation and a 2-day culture, failing the requirement of rapid dose estimation, which is a high priority in radiation emergency medicine and triag...

متن کامل

Induction of Premature Chromosome Condensation (PCC) by Calyculin A for biodosimetry

B iological dosimetry of ionizing radiation is generally performed by scoring dicentrics and/or translocations in chromosome from peripheral blood lymphocytes (pbl) at the first mitosis following in vitro growth stimulation. It is well known that after irradiation, in this procedure mitotic index is low in some individuals, so the scored mitoses might not be representative of the exposed cell p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 55  شماره 

صفحات  -

تاریخ انتشار 2014