Glycated hemoglobin (HbA1c) measurement in frozen whole blood depends on baseline values of fresh samples.

نویسندگان

  • Luigi Liotta
  • Alessandra Di Franco
  • Mario Pazzagli
  • Michaela Luconi
چکیده

Glycated hemoglobin (HbA1c) has been recently adopted as a diagnostic marker of type 2 diabetes. However, its usage is currently limited to fresh blood samples. To allow retrospective HbA1c measurement in blood banks developed in large epidemic studies, here, we contribute to validate HbA1c assessment in frozen versus fresh blood samples from a cohort of diabetic/nondiabetic adult subjects. HbA1c was measured by HPLC in 237 fresh whole blood samples and on the same samples after a 12-month storage and a further 6-month-refrozen storage. Mean HbA1c ± SD in fresh, frozen, and refrozen samples was 6.9 ± 1.2, 6.6 ± 1.1, and 6.4 ± 1.0% for the Diabetes Control and Complications Trial and 52 ± 13, 49 ± 12, and 46 ± 11 mmol/mol for the International Federation of Clinical Chemistry and Laboratory Medicine reference, respectively. A significant correlation was found between fresh/frozen and fresh/refrozen (R = 0.994 and 0.993, P < 0.001) samples. HbA1c relative error ratio (%RER) between frozen/refrozen and fresh samples significantly correlated with HbA1c and depended on fresh value range, increasing in the five HbA1c classes (<6.0, 6.0-6.5, 6.5-7, 7-8, ≥8%, corresponding to <42, 42-48, 48-53, 53-64, ≥64 mmol/mol, P < 0.001). In particular, the 6.5% (48 mmol/mol) HbA1c diagnostic cutoff of fresh samples identified two classes reflecting significant differences in %RER (2.8 ± 2.0 and 3.3 ± 1.7; P < 0.05) between frozen and fresh samples. In conclusion, our results demonstrate a high correlation between data from fresh and frozen samples, with a very limited %RER between the two measurements, which increases with baseline HbA1c levels. Accordingly, when analyzing biobank frozen specimens for diagnostic purpose, the effect of the HbA1c range should be taken into account.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of sample freezing at – 80 °C for 2–12 weeks on glycated haemoglobin (HbA1c) concentration assayed by HPLC method on Bio-Rad D-10® auto analyzer

INTRODUCTION The aim of the study was to evaluate the effect of a single freeze/thaw cycle on HbA1c concentrations measured by commercially available HPLC method. MATERIALS AND METHODS Study included 128 whole blood samples collected from diabetic patients (N = 60) and healthy volunteers (N = 68). HbA1c concentrations were measured in fresh blood samples. Then samples were frozen at - 80 °C f...

متن کامل

Glycated haemoglobin A1c measurement in stored whole blood sample is reliable for clinical use.

Glycated haemoglobin A1c (HbA1c) gives an integrated plasma glycaemia for the previous 2-3 months and its measurement is central in the management of diabetic patients. However in many developing countries because kits/regents or expertise for HbA1c measurement are not always available and the test must be conducted on fresh whole blood samples, HbA1c tests are not routinely performed Thus, thi...

متن کامل

Direct enzymatic assay for %HbA1c in human whole blood samples.

OBJECTIVES Development and validation of a direct enzymatic HbA1c assay that utilizes a single channel on chemistry auto-analyzers without the need to run separate glycated hemoglobin and total hemoglobin assays. DESIGN AND METHODS An enzyme based single channel assay was developed to measure %HbA1c in human whole blood samples. The performance characteristics of the Diazyme Direct Enzymatic ...

متن کامل

Measurement of glycated hemoglobin A1c from dried blood by turbidimetric immunoassay.

BACKGROUND Glycated hemoglobin A1c (A1C) is an important marker in the diagnosis and treatment of diabetes. Dried blood measurement of A1C is useful in large scale epidemiological evaluation of A1C, especially to assess the impact of intervention programs. The possibility of using dried blood for measurement of A1C by the immunoturbidimetric method was explored in the present study. METHOD Bl...

متن کامل

Accuracy of filter paper method for measuring glycated hemoglobin.

BACKGROUND AND OBJECTIVES Glycated hemoglobin (HbA1c) provides an accurate and reliable method to assess the glycemic control in patients with Diabetes. Its measurement is limited by the inconvenience of sample collection that requires venipuncture, sample handling and storage factors. The aim of this study was to assess the feasibility of using a dried capillary blood spot on a filter paper to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 405 1  شماره 

صفحات  -

تاریخ انتشار 2013