Adverse Interactions between ICD and Permanent Pacemaker Systems
نویسندگان
چکیده
After the introduction of the implantable cardioverter defibrillator (ICD) in clinical practice by Mirowski in 1980 [Mirowski et al., 1980] the first available devices offered only a basic ventricular pacing option. Since approximately 5-20% of patients with an indication for ICD therapy following implantation criteria at that time (secondary prevention) needed antibradycardia pacing as well, the implantation of an additional pacemaker (PM) was often necessary up to the 1990s [Sticherling et al., 1997; Brooks et al, 1995; Geiger et al., 1997]. In contrast, the modern ICD systems offer all forms of antitachycardia and antibradycardia therapy integrated in one device. However in 1997 Sticherling et al. concluded in their review about combined ICD and antibradycardia pacing therapy, that even with the introduction of integrated devices the issue of interactions will stay clinically relevant, as many candidates for ICD implantation present with an already implanted pacemaker system [Sticherling et al., 1997]. In contrast to this prediction, today more than 10 years later, through the tremendous advances in device technology as well as in implantation and revision operation methods, the patients are rare, who are fitted with two separate active cardiac implantable electronic devices (CIED) for antibradycardia and antitachycardia therapy respectively. However these patients require extreme diligence at implantation, testing, programming and follow-up to avoid potentially dangerous interactions between the devices. „Concomitant implantation of AICD and a permanent pacemaker requires an understanding of the functioning of both devices and their potential interactions“[Singer et al., 1988]
منابع مشابه
Pacemaker-ICD/Drug Interaction
When a drug is prescribed for a patient with a permanent pacemaker or an implantable cardioverter defibrillator (ICD), consideration must be given to the potential interactions. Drug effect on pacemaker performance is usually thought to cause an increase or decrease in pacing threshold. From a practical view, Class IC drugs must be used cautiously in pacemaker patients, especially in those who ...
متن کاملCombined use of non-thoracotomy cardioverter defibrillators and endocardial pacemakers.
OBJECTIVE To study the potential interactions in patients with endocardial permanent pacemakers and non-thoracotomy implantable cardioverter defibrillator (ICD) systems. DESIGN Case series and cohort study. SETTING Tertiary referral centre. PATIENTS Fifteen consecutive patients with both endocardial pacemakers (12 dual chamber and three single chamber) and non-thoracotomy ICD systems. M...
متن کاملShould implantable cardioverter-defibrillators and permanent pacemakers in patients with terminal illness be deactivated? Deactivating Implantable Cardioverter-Defibrillators and Permanent Pacemakers in Patients With Terminal Illness
The recently published 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities1 include a discussion of ethical issues surrounding the deactivation of pacemakers, implanted cardioverter-defibrillator (ICDs), and CRT devices in patients who are terminally ill. The authors rightly note that most clinicians make an ethical distinction between deactivating an ICD and deactivating a...
متن کاملIs correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...
متن کاملThe Effect of a Self-Care Program on the Quality of Life of Patients with Permanent Pacemaker
Introduction. Today, the subject of patient education as well as education for their families is mainly about acceptance of self-care by patients. Therefore, proper conditions should be provided for patients to be able to take care of themselves. This study attempts to examine the effects of a self-care program on quality of life of patients having permanent pacemaker. Methods. A quasi-experim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012