The study of statistical methods for evaluating the comparability of routine chemistry analytes among 3 routine laboratory measurement systems in China
نویسندگان
چکیده
BACKGROUND Clinical laboratory tests are important for clinicians to make diagnostic decisions, but discrepancies may directly lead to incorrect diagnosis. We would like to introduce some statistical methods to evaluate the comparability of chemistry analytes while comparing the performances of different measurement systems. METHODS We used a panel of 10 fresh-frozen single donation serum samples to assess assays for the measurement of glucose and other 13 analytes. Statistical methods used in this article include traditional statistical analysis, robust statistics, regression analysis and differences on medical decision levels (MDL). All the statistical analysis results would be evaluated. 20 Chinese tertiary hospitals accredited to ISO 15189 took part in this work. The commercial random access platforms included: Olympus (8 labs), Hitachi (6 labs) and Roche (6 labs). To compare the acceptable rates, Chi square test was used. RESULTS The statistical analysis results are as follows: (1) Coefficient of variations are between 2.8 and 3.9 %, with the slopes and intercepts of regression functions between 0.928 to 1.064 and -0.174 to 0.630, respectively. (2) The percentage of robust z-scores between -2 and 2 is bigger than 90 %. (3) The total percentages of differences on all the MDLs are: less than optimal was 31.7 % (19/60); less than desirable was 60.0 % (36/60); less than minimum was 65.0 % (39/60); more than minimum was 35.0 % (21/60). In this study, 2 laboratories (Nos. 8 and 16) were considered as poor performance by z-scores. 10 laboratories (Nos. 4, 5, 7, 8, 9, 10, 11, 14, 16 and 19) have unacceptable measurement errors on MDLs. 10 laboratories (Nos. 1, 2, 3, 6, 12, 13, 15, 17, 18, 20) can achieve mutual recognition of serum glucose testing results, including: 5 (5/8) Olympus, 2 (2/6) Hitachi and 3 (3/6) Roche. There was no significant difference among acceptable rates of the three measurements systems for the serum glucose assay. CONCLUSIONS Traditional statistical analysis, robust statistics and robust z-score, fitting linear regression equations and calculating differences on different MDLs can be used on studying the comparability and mutual recognition of clinical chemistry analytes among hospitals or laboratories in China. The mutual recognition and interchangeability of results remains jeopardized even among tertiary hospitals in China. More works and efforts should be done for improvement of the current situation of interchangeability of results in clinical laboratories in China.
منابع مشابه
Commutability of the ERM-DA470k reference material for two assays measuring serum albumin using immunochemical principles.
The standardization of measurements is a high-priority in Laboratory Medicine; its purpose being to achieve closer comparability of results for the same analyte obtained using different commercial systems (1). The promotion of result traceability to available higher-order reference measurement procedures and reference materials is the recommended approach (2). A major prerequisite for guarantee...
متن کاملState of the art in trueness and interlaboratory harmonization for 10 analytes in general clinical chemistry.
CONTEXT Harmonization and standardization of results among different clinical laboratories is necessary for clinical practice guidelines to be established. OBJECTIVE To evaluate the state of the art in measuring 10 routine chemistry analytes. DESIGN A specimen prepared as off-the-clot pooled sera and 4 conventionally prepared specimens were sent to participants in the College of American Pa...
متن کاملNecessity of Routine Repeat Testing of Critical Values in Various Working Shifts
Background & Objective: Accurate and timely reporting of critical values is an important issue. There is some doubt whether repeat testing of critical values would offer any advantage over single testing or not. The aim of this study was evaluation of utility of routine repeat testing of critical values in our referral center and to compare probable variations in different work...
متن کاملTraceability, reference systems and result comparability.
The standardisation of measurements is of high priority in laboratory medicine, its purpose being to achieve closer comparability of results obtained using routine measurement procedures. At present, there is international cooperation in developing reference measurement systems (reference methods, reference materials, and reference laboratory networks) for analytes of clinical significance. The...
متن کاملAssessment of the Trueness and Inter-Laboratory Precision of Routine Uric Acid Assays Using 4 Frozen Pooled Serum Samples Measured by the Japan Society of Clinical Chemistry's HPLC Method
BACKGROUND Reference procedures are required for evaluating the accuracy of routine analytical systems for uric acid (UA). External quality assessment (EQA) for UA has only been conducted with quality controls in China, and the results have not been published. This study was designed to investigate both the trueness and inter-laboratory precision of UA measurements among routine analytical syst...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -
تاریخ انتشار 2016