Three-dimensional imaging of vasculature and parenchyma in intact rodent organs with X-ray micro-CT.
نویسندگان
چکیده
A microcomputed tomography (micro-CT) scanner, which generates three-dimensional (3-D) images consisting of up to a billion cubic voxels, each 5-25 micron on a side, and which has isotropic spatial resolution, is described. Its main components are a spectroscopic X-ray source that produces selectable primary emission peaks at approximately 9, 18, or 25 keV and a fluorescing thin crystal plate that is imaged (at selectable magnification) with a lens onto a 2.5 x 2.5-cm, 1,024 x 1,024-pixel, charge-coupled device (CCD) detector array. The specimen is positioned close to the crystal and is rotated in 721 equiangular steps around 360 degrees between each X-ray exposure and its CCD recording. Tomographic reconstruction algorithms, applied to these recorded images, are used to generate 3-D images of the specimen. The system is used to scan isolated, intact, fixed rodent organs (e.g., heart or kidney) with the image contrast of vessel lumens enhanced with contrast medium. 3-D image display and analysis are used to address physiological questions about the internal structure-to-function relationships of the organs.
منابع مشابه
Three-dimensional microcomputed tomography of renal vasculature in rats.
Current microscopic methods to view renal microvasculature reveal only a very limited portion of the total renal volume. Identification of connectivity for postglomerular vessels in the cortex and the medulla during functional states related to changes in sodium excretion will help better to understand the coupling of renal vasculature to tubular function. The purpose of this study was to inves...
متن کاملInvestigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT
Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...
متن کاملThree-dimensional imaging of whole rodent organs using optical computed and emission tomography.
We explore the potential of optical computed tomography (optical-CT) and optical emission computed tomography (optical-ECT) in a new area-whole organ imaging. The techniques are implemented on an in-house prototype benchtop system with improved image quality and the capacity to image larger samples (up to 3 cm) than previous systems based on stereo microscopes. Imaging performance tests confirm...
متن کاملThe use of microcomputed tomography to study microvasculature in small rodents.
Appropriate nephron function is dependent on the intrarenal arrangement of blood vessels. The preferred and primary means to study the architecture of intrarenal circulation has been by filling it with opaque substances such as india ink, radio-opaque contrast material, or various polymers for study by light or scanning electron microscopy. With such methodologies, superficial vessels may obscu...
متن کاملVisualization and Quantitative 3D Analysis of Intraocular Melanoma and Its Vascularization in a Hamster Eye
A tumor vasculature network undergoes intense growth and rebuilding during tumor growth. Traditionally, vascular networks are histologically examined using parameters such as vessel density determined from two-dimensional slices of the tumor. Two-dimensional probing of a complicated three-dimensional (3D) structure only provides partial information. Therefore, we propose the use of microcompute...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The American journal of physiology
دوره 275 3 Pt 2 شماره
صفحات -
تاریخ انتشار 1998