In vivo assessment of the effect of controlled high- and low-frequency mechanical loading on peri-implant bone healing.

نویسندگان

  • Xiaolei Zhang
  • Katleen Vandamme
  • Antonia Torcasio
  • Toru Ogawa
  • G Harry van Lenthe
  • Ignace Naert
  • Joke Duyck
چکیده

The aim of this study was to investigate the effect of controlled high- (HF) and low-frequency (LF) mechanical loading on peri-implant bone healing. Custom-made titanium implants were inserted in both tibiae of 69 adult Wistar rats. For every animal, one implant was loaded by compression through the axis of tibia (test), whereas the other one was unloaded (control). The test implants were randomly distributed among four groups receiving different loading regimes, which were determined by ex vivo calibration. Within the HF (40 Hz) or LF (2 Hz) loading category, the magnitudes were chosen as low- (LM) and high-magnitude (HM), respectively, leading to constant strain rate amplitudes for the two frequency groups. This resulted in the four loading regimes: (i) HF-LM (40 Hz-0.5 N); (ii) HF-HM (40 Hz-1 N); (iii) LF-LM (2 Hz-10 N); and (iv) LF-HM (2 Hz-20 N) loading. Loading was performed five times per week and lasted for one or four weeks. Tissue samples were processed for histology and histomorphometry (bone-to-implant contact, BIC; and peri-implant bone fraction, BF) at the cortical and medullar level. Data were analysed statistically with ANOVA and paired t-tests with the significance level set at 0.05. For the one-week experiments, an increased BF adjacent to the implant surface at the cortical level was exclusively induced by the LF-HM loading regime (2 Hz-20 N). Four weeks of loading resulted in a significant effect on BIC (and not on BF) in case of HF-LM loading (40 Hz-0.5 N) and LF-HM loading (2 Hz-20 N): BIC at the cortical level significantly increased under both loading regimes, whereas BIC at the medullar level was positively influenced only in case of HF-LM loading. Mechanical loading at both HF and LF affects osseointegration and peri-implant BF. Higher loading magnitudes (and accompanying elevated tissue strains) are required under LF loading to provoke a positive peri-implant bone response, compared with HF loading. A sustained period of loading at HF is needed to result in an overall enhanced osseointegration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی رادیوگرافیک اثر بارگذاری تدریجی بر روی تغییرات استخوان کرستال و تراکم استخوان اطراف ایمپلنت‌های تک واحدی خلف ماگزیلا

Background and Aim: The aim of this clinical study was to determine the effectiveness of progressive loading procedures on preserving crestal bone height and improving peri-implant bone density around maxillary implants restored with single crowns by an accurate longitudinal radiographic assessment technique. Materials and Methods: Eleven Micro-Thread Osseo Speed dental implants were place...

متن کامل

Low-magnitude high-frequency loading, by whole-body vibration, accelerates early implant osseointegration in ovariectomized rats

Osteoporosis deteriorates jaw bone quality and may compromise early implant osseointegration and early implant loading. The influence of low‑magnitude, high‑frequency (LMHF) vibration on peri‑implant bone healing and implant integration in osteoporotic bones remains poorly understood. LMHF loading via whole‑body vibration (WBV) for 8 weeks has previously been demonstrated to significantly enhan...

متن کامل

Enhancement of Implant Osseointegration by High-Frequency Low-Magnitude Loading

BACKGROUND Mechanical loading is known to play an important role in bone remodelling. This study aimed to evaluate the effect of high- and low-frequency axial loading, applied directly to the implant, on peri-implant bone healing and implant osseointegration. METHODOLOGY Titanium implants were bilaterally installed in rat tibiae. For every animal, one implant was loaded (test) while the other...

متن کامل

تعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود

Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...

متن کامل

Determining the prevalence of peri-implantitis in patients one year after prosthetic loading in Khorramabad in 2021

Background and Aims: Although dental implants have become a successful and predictable ong-term treatment for patients, not all implant treatments are necessarily successful and pre-implant diseases are spreading. The aim of this study was to determine the prevalence of peri-implantitis in patients one year after prosthetic loading in Khorramabad in 2021. Materials and Methods: In this cross-s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the Royal Society, Interface

دوره 9 72  شماره 

صفحات  -

تاریخ انتشار 2012