Computerized expert system for evaluation of automated visual fields from the Ischemic Optic Neuropathy Decompression Trial: methods, baseline fields, and six-month longitudinal follow-up.

نویسنده

  • Steven E Feldon
چکیده

PURPOSE To validate a computerized expert system evaluating visual fields in a prospective clinical trial, the Ischemic Optic Neuropathy Decompression Trial (IONDT). To identify the pattern and within-pattern severity of field defects for study eyes at baseline and 6-month follow-up. DESIGN Humphrey visual field (HVF) change was used as the outcome measure for a prospective, randomized, multicenter trial to test the null hypothesis that optic nerve sheath decompression was ineffective in treating nonarteritic anterior ischemic optic neuropathy and to ascertain the natural history of the disease. METHODS An expert panel established criteria for the type and severity of visual field defects. Using these criteria, a rule-based computerized expert system interpreted HVF from baseline and 6-month visits for patients randomized to surgery or careful follow-up and for patients who were not randomized. RESULTS A computerized expert system was devised and validated. The system was then used to analyze HVFs. The pattern of defects found at baseline for patients randomized to surgery did not differ from that of patients randomized to careful follow-up. The most common pattern of defect was a superior and inferior arcuate with central scotoma for randomized eyes (19.2%) and a superior and inferior arcuate for nonrandomized eyes (30.6%). Field patterns at 6 months and baseline were not different. For randomized study eyes, the superior altitudinal defects improved (P = .03), as did the inferior altitudinal defects (P = .01). For nonrandomized study eyes, only the inferior altitudinal defects improved (P = .02). No treatment effect was noted. CONCLUSIONS A novel rule-based expert system successfully interpreted visual field defects at baseline of eyes enrolled in the IONDT.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and validation of a computerized expert system for evaluation of automated visual fields from the Ischemic Optic Neuropathy Decompression Trial

BACKGROUND The objective of this report is to describe the methods used to develop and validate a computerized system to analyze Humphrey visual fields obtained from patients with non-arteritic anterior ischemic optic neuropathy (NAION) and enrolled in the Ischemic Optic Neuropathy Decompression Trial (IONDT). The IONDT was a multicenter study that included randomized and non-randomized patient...

متن کامل

Ischemic Optic Neuropathy Decompression Trial: twenty-four-month update.

OBJECTIVE To describe visual acuity outcomes of patients in the Ischemic Optic Neuropathy Decompression Trial (IONDT) after 24 months of follow-up. DESIGN The IONDT is a single-masked, multicenter, randomized clinical trial. SETTINGS Patients were evaluated and followed up at 25 clinical centers located throughout the United States. Data were sent to and analyzed at a central coordinating c...

متن کامل

Surgery for nonarteritic anterior ischemic optic neuropathy.

BACKGROUND Nonarteritic ischemic optic neuropathy is characterized by sudden and painless loss of vision in one eye, accompanied by pallid swelling of the optic disc. Although various medical interventions, such as corticosteroids and phenytoin sodium, have been used to treat nonarteritic ischemic optic neuropathy, no therapy has been proven effective. OBJECTIVES The objective of this review ...

متن کامل

Visual fields in neuro-ophthalmology

Visual field assessment is important in the evaluation of lesions involving the visual pathways and should be performed at baseline and periodically in the follow-up. Standard automated perimetry has been shown to be adequate in neuro-ophthalmic practise and is now the technique of choice for a majority of practitioners. Goldman kinetic visual fields are useful for patients with severe visual a...

متن کامل

Clinical profile of patients with nonarteritic anterior ischemic optic neuropathy presented to a referral center from 2003 to 2008.

BACKGROUND We conducted this study to report the demographics and clinical profile of patients with nonarteritic anterior ischemic optic neuropathy referred to a referral neuro-ophthalmology center in Iran. METHODS During a five-year period, 107 patients with nonarteritic anterior ischemic optic neuropathy were studied. A detailed history of previous or current systemic diseases was obtained ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Transactions of the American Ophthalmological Society

دوره 102  شماره 

صفحات  -

تاریخ انتشار 2004