Audiometric Outcome Comparison between Titanium Prosthesis and Molded Autologous Material.

نویسندگان

  • Tiago Órfão
  • Sara Júlio
  • José Filipe Ramos
  • Cláudia Camila Dias
  • Helena Silveira
  • Margarida Santos
چکیده

OBJECTIVE To evaluate and compare the audiometric outcomes of ossicular reconstruction with titanium prosthesis and autologous material. STUDY DESIGN Retrospective cohort study. SETTING Tertiary referral center. SUBJECTS AND METHODS Audiometric results of consecutive patients who performed ossiculoplasty with titanium prosthesis (n = 43) or autologous material (n = 48), from October 2008 to December 2011, were reviewed retrospectively and compared. The association between air-bone gain and age, ossiculoplasty material (autologous or titanium), preoperative diagnosis (chronic otitis media without cholesteatoma, cholesteatoma, or conductive hearing loss with intact tympanic membrane), and type of surgery (tympanoplasty, canal wall-down mastoidectomy, or canal wall-up mastoidectomy) was explored using regression analysis. RESULTS Preoperative audiometric evaluation did not show differences between titanium and autologous groups in air-bone gap and pure-tone average. A postoperative decrease of 11.0 dB in air-bone gap and 12.4 dB in pure-tone average was observed in titanium ossiculoplasty compared with a reduction of 4.0 dB in air-bone gap and 5.1 dB in pure-tone average when autologous reconstruction was used. Mann-Whitney test revealed superior results in the titanium group compared with autologous reconstruction patients in air-bone gap (P = .02) and pure-tone average (P = .02). However, no statistically significant associations were observed after multivariate linear regression analysis of air-bone gap gain when adjusted for age, ossiculoplasty material, type of surgery, and preoperative diagnosis. One titanium prosthesis extrusion occurred during follow-up (2%). CONCLUSION Audiometric results achieved by titanium prosthesis are promising, but significant differences compared with autologous ossiculoplasty were not present.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Titanium vs. Polycel Total Ossicular Replacement Prosthesis

Introduction: Even though modern technology progresses so rapidly, annals of otology are replete with so many challenging article, which often compare various types of prosthesis. Since there has not been a prospective randomized clinical trial study which compares the hearing result of total ossicular replacement prosthesis made of Titanium with omega connector and Polycel in the literature, w...

متن کامل

Investigating the Impact of Knee Prosthesis in Patients’ Body on Radiation Dose Distribution: A Monte Carlo Approach

Introduction: Metal prostheses in patients affect the radiotherapy dose distribution. Metal prostheses with high density and atomic number cause major changes in scattering and attenuation of radiation. The present study aims to assess the impact of metal knee prosthesis with various dimensions and materials on radiotherapy dose distribution. Material and Methods: In this research, the Varian L...

متن کامل

Comparison of Titanium vs. Polycel Total Ossicular Replacement Prosthesis

INTRODUCTION Even though modern technology progresses so rapidly, annals of otology are replete with so many challenging article, which often compare various types of prosthesis. Since there has not been a prospective randomized clinical trial study which compares the hearing result of total ossicular replacement prosthesis made of Titanium with omega connector and Polycel in the literature, we...

متن کامل

Total Ossicular Replacement Prosthesis: A New Fat Interposition Technique

Objective To compare audiometric results between the standard total ossicular replacement prosthesis (TORP-S) and a new fat interposition total ossicular replacement prosthesis (TORP-F) in pediatric and adult patients and to assess the complication and the undesirable outcome. Study design This is a retrospective study. Methods This study included 104 patients who had undergone titanium imp...

متن کامل

Comparison of the Effectiveness of teflon piston and titanium stapes prosthesis in hearing improvement

Background & objectives: The aim of this study was to compare the effectiveness of two stapes prostheses in hearing improvement of patients undergoing stapes surgery for otosclerosis.   Materials & Methods: In this retrospective and descriptive study, the charts of 291 stapedectomies performed by one surgeon (first author) from 1997 to 2011 in Imam Khomeini and Apadana hospitals of Ahvaz were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery

دوره 151 2  شماره 

صفحات  -

تاریخ انتشار 2014