A mechanical analysis of the closed Hancock heart valve prosthesis.

نویسندگان

  • E P Rousseau
  • A A van Steenhoven
  • J D Janssen
چکیده

In order to obtain mechanical specifications for the design of an artificial leaflet valve prosthesis, a geometrically non-linear numerical model is developed of a closed Hancock leaflet valve prosthesis. In this model, the fibre reinforcement of the leaflet and the viscoelastic properties of frame and leaflets are incorporated. The calculations are primarily restricted to 1/6 part of the valve and a time varying pressure load is applied. The calculations are verified experimentally by measuring the commissure displacements and leaflet centre displacement of a Hancock valve. The numerically obtained commissure displacements are found to be linearly dependent on the pressure load, and the slope of the curves is hardly dependent on loading type and loading velocity. Experimentally a difference is found between the three commissure displacements, which is also predicted numerically using a simplified asymmetric total valve model. Besides, experimentally a clear dependency of commissure displacements on frame size is found. For the leaflet centre displacement, a qualitative agreement exists between numerical prediction and experimental result, although the numerical predicted values are systematically higher. The numerically obtained stress distributions revealed that the maximum von Mises intensity in the membranes occurs in the vicinity of the commissure in the free leaflet area (0.2 N mm-2). Wrinkling of the membranes may occur in the coaptation area near the leaflet suspension. The maximum fibre stress is found near the aortic ring in the fibres which form the boundaries of the coaptation area (0.64 N mm-2). These locations seem to correlate with some common regions of tissue valve failure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.

Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...

متن کامل

Twelve-year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses.

BACKGROUND Patients undergoing heart-valve replacement may receive a mechanical prosthesis, necessitating lifelong anticoagulant treatment, or a porcine bioprosthesis, which involves no absolute need for anticoagulants. METHODS We carried out a randomized, prospective trial to compare the durability of the Bjork-Shiley mechanical prosthesis (spherical tilting-disk model) and the incidence of ...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

Cardiac bioprostheses in the 1990s.

T he first successful heart valve replacements were carried out in 1960 with the use of mechanical prostheses.1-3 Because of the risk of throm-boembolism that is inherent to all mechanical prosthe-ses and the hazards of continuous anticoagulation, fewer thrombogenic tissue valves were developed.4,5 In the early 1960s, homograft replacement of the aortic valve was reported,6'7 and shortly therea...

متن کامل

Fabrication and characterization of nanofibrous tricuspid valve scaffold based on polyurethane for heart valve tissue engineering

Objective(s): Tissue engineering represents a new approach to solve the current complications of the heart valve replacements by offering viable valve prosthesis with growth and remodeling capability. In this project, electrospinning and dip coating techniques were used to fabricate heart valve constructs from medical grade polyurethane (PU). Methods: Fir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomechanics

دوره 21 7  شماره 

صفحات  -

تاریخ انتشار 1988