Generation of accurate aortic pressure waves from calibrated upper limb pressure waveforms.
نویسنده
چکیده
Fourteen years ago, Chen Chen-Huan et al. from Baltimore1 were the first to validate use of a transfer function method for generation of the aortic from the radial artery pressure waveform. This technique had the potential capacity to link the century old brachial cuff sphygmomanometer with the even older clinical method of palpating or directly recording the radial arterial pressure wave. There was a clear prospect of merging the two so as to generate central aortic pressure, as a simple procedure in a physician’s office. Such a view has been under attack and scrutiny since. In the process of different investigations, which entailed measurements of intra-arterial and cuff pressures in the aorta and upper limb, it became apparent that the greatest inaccuracy in using any method to generate central pressure was the difference—often vast—between cuff and intra-arterial pressure in the upper limb. This problem is intrinsic to the cuff and has not been overcome. Hopefully it will, and soon. In this edition of American Journal of Hypertension, Chen Chen-Huan and colleagues, now in Taiwan, have conducted an elegant study,2 to answer key questions that have arisen over 14 years, through avoiding the various pitfalls which have swallowed others. They recorded simultaneously, at cardiac catheterisation, high-fidelity pressure waves in the ascending aorta and brachial artery, together with indirect pressure by brachial cuff in the opposite arm. Thereby, they could assess the errors that result from the sensor (intra-arterial or tonometer), the transfer function process, and the brachial cuff system in calculation of ascending aortic pressure. Their findings were that the output errors for measurement of central aortic systolic, diastolic, and pulse pressures were identical (<1mm Hg) to the input errors in measurement of the brachial values by cuff. In other words, the transfer function was accurate and could be used whenever the arm pulse waveform could be accurately recorded. Any significant inaccuracy was attributable to the cuff itself. This view conforms with recent data from Kips et al.3 which found a very close correlation from waveforms measured by radial tonometry, and those of O’Rourke and Takazawa.4 The latter, noting that while central aortic pressure is superior to brachial, the acknowledged value of brachial pressure is retained when central aortic pressure is expressed in terms of brachial pressure (even though the absolute values were not expected to be the same as when actually measured invasively). The findings of all the above1–4 are followed when the transfer function is used as originally described,5 by calibrating the radial artery pressure wave, measured by applanation tonometry, to the best available measure of arterial pressure; this was then and still is the brachial cuff sphygmomanometer value, obtained according to current guidelines.
منابع مشابه
Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform.
Pressure wave reflection in the upper limb causes amplification of the arterial pulse so that radial systolic and pulse pressures are greater than in the ascending aorta. Wave transmission properties in the upper limbs (in contrast to the descending aorta and lower limbs) change little with age, disease, and drug therapy in adult humans. Such consistency has led to use of a generalized transfer...
متن کاملApplication of the N-point moving average method for brachial pressure waveform-derived estimation of central aortic systolic pressure.
The N-point moving average (NPMA) is a mathematical low-pass filter that can smooth peaked noninvasively acquired radial pressure waveforms to estimate central aortic systolic pressure using a common denominator of N/4 (where N=the acquisition sampling frequency). The present study investigated whether the NPMA method can be applied to brachial pressure waveforms. In the derivation group, simul...
متن کاملEffect of non-invasive calibration of radial waveforms on error in transfer-function-derived central aortic waveform characteristics.
Transfer function techniques are increasingly used for non-invasive estimation of central aortic waveform characteristics. Non-invasive radial waveforms must be calibrated for this purpose. Most validation studies have used invasive pressures for calibration, with little data on the impact of non-invasive calibration on transfer-function-derived aortic waveform characteristics. In the present s...
متن کاملValidation of the transfer function technique for generating central from peripheral upper limb pressure waveform.
Central aortic pressure waveforms can be calculated from the radial artery pressure waveform using a generalized transfer function to correct for pressure wave distortion in the upper limb. Although validated to standards conventionally applied, reservations are still expressed on use of this process, because of the relatively small number of patients from whom appropriate invasive data were ob...
متن کاملComparison of blood pressure measurements on the upper and lower extremities during spinal anesthesia
Introduction: During spinal anesthesia, measurement of blood pressure is often obtained by an indirect method using an inflatable cuff on the upper arm. The relationship between the blood pressure measurements at the two sites in patients undergoing spinal anesthesia is unclear. This study was designed to evaluate the difference observed in systolic blood pressure (SBP) taken from the upp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of hypertension
دوره 24 12 شماره
صفحات -
تاریخ انتشار 2011