An Accuracy Study of the Intracavitary Electrocardiogram (IC-ECG) Guided Peripherally Inserted Central Catheter Tip Placement among Neonates
نویسندگان
چکیده
OBJECTIVE To explore the clinical application of the intracavitary electrocardiogram (IC-ECG) guided Peripherally Inserted Central Catheter (PICC) tip placement among neonates. BACKGROUND the ECGs of neonates are difficult to perform and their wave shapes are of doubtful accuracy due to various interfering factors. METHOD 115 neonates were admitted to perform PICC guided by IC-ECG. Logistic regression was performed to analyze all possible influencing factors of the accuracy from the tip placement. The puncture site of the PICC, gestational age, height, weight, basal P/R amplitude and positioning P/R amplitude might be related to the accuracy of IC-ECG location. RESULT The accuracy in the lower extremity was higher than that in the upper extremity. Multivariate logistic regression analysis showed that the weight (Odds Ratio (OR)=1.93, 95%Confidence Interval(CI):1.06-3.50) and positioning P/R amplitude (OR=32.33, 95%CI: 2.02-517.41) are statistically significant risks to the accuracy PICC tip placement. CONCLUSIONS Possible methods to improve the accuracy might be Catheterizing through lower extremity, keeping the neonates calm, enhancing the electrocardiogram signal and strengthening technical training. Therefore it is practical to perfrom a tip placement by the dynamic change in the P waves from an electrocardiogram (ECG) guided PICC among neonates and as reliable as using X-rays.
منابع مشابه
Superior success rate of intracavitary electrocardiogram guidance for peripherally inserted central catheter placement in patients with cancer: A randomized open-label controlled multicenter study
BACKGROUND Intracavitary electrocardiogram (IC ECG) guidance emerges as a new technique for peripherally inserted central catheters (PICCs) placement and demonstrates many potential advantages in recent observational studies. AIMS To determine whether IC ECG-guided PICCs provide more accurate positioning of catheter tips compared to conventional anatomical landmarks in patients with cancer un...
متن کاملFactors Influencing Intracavitary Electrocardiographic P-Wave Changes during Central Venous Catheter Placement
Amplitude changes in the P-wave of intracavitary electrocardiography have been used to assess the tip placement of central venous catheters. The research assessed the sensitivity and specificity of this sign in comparison with standard radiographic techniques for tip location, focusing on factors influencing its clinical utility. Both intracavitary electrocardiography guided tip location and X-...
متن کامل[Initial placement of the peripherally inserted central catheter's tip in neonates].
This is a cross-sectional study aiming to identify the initial tip position of peripherally inserted central catheters (PICC) and to verify the prevalence of success in inserting such catheters in neonates. The study was carried out in the neonatal care unit of Hospital das Clinicas, Universidade de São Paulo. Data were collected prospectively from March to September 2006. 37 neonates underwent...
متن کاملCardiac tamponade: a rare but preventable complication of central venous catheter in neonates.
Pericardial effusion with cardiac tamponade is a rare and life-threatening complication of peripherally inserted central catheter (PICC) in a neonate. We report a 33-week preterm neonate who had sudden clinical deterioration at day seven of total parenteral nutrition regime via PICC. Recognition of pericardial effusion with cardiac tamponade in neonates with a PICC requires a high index of susp...
متن کاملEffect of using static ultrasound technique on peripherally inserted central catheters’ insertion success rate in neonates in a neonatal intensive care unit
BACKGROUND Peripheral insertion of central catheters can be difficult in neonates. We compared the success rates of peripherally inserted central catheters by two methods of using static ultrasound and traditional technique (vein visualization and palpation) in neonates. MATERIALS AND METHODS In a prospective randomized, controlled trial, 52 neonates with birth weight lower than 1500 g in a l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2017