High-resolution imaging of microvasculature in human skin in-vivo with optical coherence tomography

نویسندگان

  • Gangjun Liu
  • Wangcun Jia
  • Victor Sun
  • Bernard Choi
  • Zhongping Chen
چکیده

In this paper, the features of the intensity-based Doppler variance (IBDV) method were analyzed systemically with a flow phantom. The effects of beam scanning density, flow rate and the time interval between neighboring A-lines on the performance of this method were investigated. The IBDV method can be used to quantify the flow rate and its sensitivity can be improved by increasing the time interval between the neighboring A-lines. A higher sensitivity IBDV method that applies the algorithm along the slower scan direction was proposed. In comparison to laser speckle imaging maps of blood flow, we demonstrated the ability of the method to identify vessels with altered blood flow. In clinical measurements, we demonstrated the ability of the method to image vascular networks with exquisite spatial resolution and at depths up to 1.2 mm in human skin. These results collectively demonstrated the potential of the method to monitor the microvasculature during disease progression and in response to therapeutic intervention.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Visualization of Labyrinthine Structure with Optical Coherence Tomography

Introduction:Visualization of inner ear structures is a valuable strategy for researchers and clinicians working on hearing pathologies. Optical coherence tomography (OCT) is a high-resolution imaging technology which may be used for the visualization of tissues. In this experimental study we aimed to evaluate inner ear anatomy in well-prepared human labyrinthine bones.Materials and Methods:Thr...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Full-field optical coherence tomography: a new technology for 3D high-resolution skin imaging.

BACKGROUND/AIMS Full-field optical coherence tomography (FFOCT) is a new imaging technology that can provide 3D micron-level resolution and is suited for high-resolution imaging of biological tissue. The aim of this study was to evaluate its capacity and potential for imaging human epidermis and dermis and various skin pathologies in ex vivo and in vivo conditions. METHODS Non-fixed and fixed...

متن کامل

Computed optical interferometric tomography for high-speed volumetric cellular imaging.

Three-dimensional high-resolution imaging methods are important for cellular-level research. Optical coherence microscopy (OCM) is a low-coherence-based interferometry technology for cellular imaging with both high axial and lateral resolution. Using a high-numerical-aperture objective, OCM normally has a shallow depth of field and requires scanning the focus through the entire region of intere...

متن کامل

High-resolution optical Doppler tomography for in vitro and in vivo fluid flow dynamics.

BACKGROUND The objective of our research was to use a noninvasive tomographic imaging technique with high spatial resolution (2-15 microm) to characterize and monitor fluid flow and the microvasculature in highly scattering biological tissues at user-specified discrete locations. METHODS The technique of optical Doppler tomography (ODT) combines laser Doppler flowmetry (LDF) with optical cohe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2012