Electrophysiological mapping for the implantation of deep brain stimulators for Parkinson's disease and tremor.

نویسندگان

  • Robert E Gross
  • Paul Krack
  • Maria C Rodriguez-Oroz
  • Ali R Rezai
  • Alim-Louis Benabid
چکیده

The vast majority of centers use electrophysiological mapping techniques to finalize target selection during the implantation of deep brain stimulation (DBS) leads for the treatment of Parkinson's disease and tremor. This review discusses the techniques used for physiological mapping and addresses the questions of how various mapping strategies modify target selection and outcome following subthalamic nucleus (STN), globus pallidus internus (GPi), and ventralis intermedius (Vim) deep brain stimulation. Mapping strategies vary greatly across centers, but can be broadly categorized into those that use microelectrode or semimicroelectrode techniques to optimize position prior to implantation and macrostimulation through a macroelectrode or the DBS lead, and those that rely solely on macrostimulation and its threshold for clinical effects (benefits and side effects). Microelectrode criteria for implantation into the STN or GPi include length of the nucleus recorded, presence of movement-responsive neurons, and/or distance from the borders with adjacent structures. However, the threshold for the production of clinical benefits relative to side effects is, in most centers, the final, and sometimes only, determinant of DBS electrode position. Macrostimulation techniques for mapping, the utility of microelectrode mapping is reflected in its modification of electrode position in 17% to 87% of patients undergoing STN DBS, with average target adjustments of 1 to 4 mm. Nevertheless, with the absence of class I data, and in consideration of the large number of variables that impact clinical outcome, it is not possible to conclude that one technique is superior to the other in so far as motor Unified Parkinson's Disease Rating Scale outcome is concerned. Moreover, mapping technique is only one out of many variables that determine the outcome. The increase in surgical risk of intracranial hemorrhage correlated to the number of microelectrode trajectories must be considered against the risk of suboptimal benefits related to omission of this technique.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal design of a vibration absorber for tremor control of arm in Parkinson's disease

Because the underlying physiology of pathological tremor in a Parkinson's patient is not well understood, the existing physical and drug therapies have not been successful in tremor treatment. Different mathematical modeling of such vibration has been introduced to investigate the problem and reduce the existing vibration. Most of the models have represented the induced vibration as a sinusoida...

متن کامل

Anatomical situation of the subthalamic nucleus (STN) from midcommissural point (MCP) in Parkinson\'s disease patients underwent deep brain stimulation (DBS): an MRI targeting study

  Abstract   Introduction: It is demonstrated that the degree of clinical improvement in   Parkinson's disease (PD) achieved by deep brain stimulation (DBS) is largely dependent   on the accuracy of lead placement. In addition, individual variability in the   situation of subthalamic nucleus (STN) is responsible for spatial inter-individual   fluctuations of the real patient's target.   Objecti...

متن کامل

Placement of the Internal Pulse Generator for Deep Brain Stimulation in the Upper Back to Prevent Fracture of the Extension Wire due to Generator Rotation: Case Report

Deep brain stimulation (DBS) is a common surgical procedure used for the treatment of Parkinson's disease (PD) and essential tremor. A potential complication of this procedure is hardware failure. The authors report a case of DBS hardware failure in which repeated fractures of the extension wire were caused by abnormal rotational movements of the IPG placed in the loose subclavicular tissue of ...

متن کامل

Quantification of Parkinson Tremor Intensity Based On EMG Signal Analysis Using Fast Orthogonal Search Algorithm

The tremor injury is one of the common symptoms of Parkinson's disease. The patients suffering from Parkinson's disease have difficulty in controlling their movements owing to tremor. The intensity of the disease can be determined through specifying the range of intensity values of involuntary tremor in Parkinson patients. The level of disease in patients is determined through an empirical rang...

متن کامل

Uniform qualitative electrophysiological changes in postoperative rest tremor.

Ablation and deep brain stimulation (DBS) can treat pharmacologically uncontrollable tremor. Here, we compared the postoperative electrophysiological changes in resting hand tremor after 32 ablations and 12 DBS implantations in patients with severe tremor-dominant idiopathic Parkinson's disease (PD) and essential tremor (ET). Short- and long-term accelerometric data were acquired after surgery ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Movement disorders : official journal of the Movement Disorder Society

دوره 21 Suppl 14  شماره 

صفحات  -

تاریخ انتشار 2006