Electrode interaction in cochlear implant recipients: comparison of straight and contour electrode arrays.
نویسندگان
چکیده
The degree of overlap among cochlear nerve fibers stimulated by different electrodes results in electrode interaction, which has been shown to have a significantly deleterious effect on speech recognition performance in multi-electrode cochlear implant users. The Nucleus CI24R(CS) Contour array, which lies substantially closer to the modiolus than the CI24M straight array, is expected to exhibit narrower excitation patterns. The neural response telemetry (NRT) 3.0 software provides a method of measuring the spread of neural excitation by presenting the masker and probe pulses on different intra-cochlear electrode bands. Nine pairs of children, using Nucleus CI24M/CI24R(CS) cochlear implants with a similar etiology and duration of deafness, insertion depth, age of implantation and loudest acceptable presentation level (LAPL) in NRT sessions, participated in the study. Profiles of the spread of neural excitation stimulated at the LAPL at 3 probe locations were examined for each pair of the 2 types of electrode array. The spread of neural excitation with respect to array type and location revealed significant effects (p < 0.001; p = 0.002) and no interaction between array type and probe location (p = 0.559). The results demonstrated that the Contour array improved electrode discrimination, especially for the electrodes at the basal end of the cochlea. The findings have implications for future electrode array design and current implant mapping strategies.
منابع مشابه
An overview of cochlear implant electrode array designs
Cochlear implant electrode arrays are designed with specific characteristics that allow for the preservation of intra-cochlear structures during the insertion process, as well as during explantation. Straight lateral wall (LW) electrode arrays and pre-curved modiolar hugging (MH) electrode arrays are the two types that are commercially available. Although there is a third type of electrode arra...
متن کاملPerimodiolar electrode position: Effects on thresholds, comfort levels, impedance measurements, and neural response telemetry
OBJECTIVE: This multicenter study describes the effects of perimodiolar electrode position on 50 adult patients (31 with an implanted Nucleus 24 Contour perimodiolar hugging electrode array [Cochlear Limited, Lane Cove, NSW, Australia] and 19 with an implanted straight electrode array) with a severe-to-profound sensorineural hearing loss. MATERIALS AND METHODS: In all patients, intraoperative i...
متن کاملInvestigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan
Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...
متن کاملComparison of electrically evoked whole-nerve action potential and electrically evoked auditory brainstem response thresholds in nucleus CI24R cochlear implant recipients.
In this study, differences between electrically evoked whole-nerve action potential (EAP) and electrically evoked auditory brainstem response (EABR) measurements within Nucleus CI24R cochlear implant recipients were evaluated. Precurved modiolus-hugging internal electrode arrays, such as the CI24R, are designed to provide more direct stimulation of neural elements of the modiolus. If the electr...
متن کاملEvaluation of the Slope of Amplitude Growth Function Changes of the Electrically Evoked Action Potential in Three Months after Receiving the Device in Children with Cochlear Implant
Objective: In neural response telemetry, intracochlear electrodes stimulate the auditory nerve and record the neural responses. The electrical stimulation is sent to the auditory nerve by an electrode and the resulted response, called electrically evoked compound action potential, is recorded by an adjacent electrode. The most important clinical applications of this test are evaluation and moni...