Physiologic determinants of ventilator dependence in long-term mechanically ventilated patients.
نویسندگان
چکیده
To investigate the pathophysiologic mechanisms of ventilator dependence, we took physiologic measurements in 28 patients with COPD and 11 postcardiac surgery (PCS) patients receiving long-term mechanical ventilation during a spontaneous breathing trial, and in 20 stable, spontaneously breathing patients matched for age and disease. After 40 +/- 14 min of spontaneous breathing, 20 of 28 patients with COPD and all 11 PCS patients were judged ventilator-dependent (VD). We found that in the 31 VD patients tidal volume was low (VT: 0.36 +/- 0.12 and 0.31 +/- 0.08 L for COPD and PCS, respectively), neuromuscular drive was high (P(0.1): 5.6 +/- 1. 6 and 3.9 +/- 1.9 cm H(2)O), inspiratory muscle strength was reduced (Pdi(max): 42 +/- 12 and 28 +/- 15 cm H(2)O), and lung mechanics were abnormal, particularly PEEPi (5.9 +/- 3.0 cm H(2)O) and lung resistance (22.2 +/- 9.2 cm H(2)O/L/s) in COPD. The load/capacity balance was altered (Pdi/Pdi(max) and Ppl/Ppl(max) > 0.4) and the effective inspiratory impedance was high (P(0.1)/VT/TI >/= 10 cm H(2)O/L/s). Failure to wean occurred in patients with f/VT > 105 breaths/min/L and 56% of patients with COPD with f/VT < 80 breaths/min/L. Those who failed despite a low f/VT ( < 80 breaths/min/L) either showed ineffective inspiratory efforts, which artificially lowered f/ VT (n = 8), or did not increase breathing frequency (n = 5), but P(0.1) and P(0.1)/VT/TI were as high as in other VD patients. In the 31 VD patients, Pa(CO(2)) increased during the weaning trial (+12.3 +/- 8.0 mm Hg). We conclude that in the presence of a high drive to breathe, the imbalance between increased work load and reduced inspiratory muscle strength causes respiratory distress and CO(2) retention. Noninvasive measurements (breathing pattern, P(0.1), P(0.1)/ VT/TI) may give better insight into weaning failure useful in clinical decision-making, particularly in patients with COPD not showing rapid shallow breathing (56% in this study).
منابع مشابه
The effect of Therapeutic Touch on Physiological Variables of Mechanically Ventilated Patients in Intensive Care Units
Background: Underlying diseases and aggressive procedures, such as different types of surgery and care, for patients with critical conditions in intensive care units (ICU) may be associated with physiological disorders. Objectives: This study intended to determine the effect of therapeutic touch on physiological variables of patients undergoing mechanical ventilation in ICU. Methods: This...
متن کاملAn evidence-based recommendation on bed head elevation for mechanically ventilated patients
INTRODUCTION A semi-upright position in ventilated patients is recommended to prevent ventilator-associated pneumonia (VAP) and is one of the components in the Ventilator Bundle of the Institute for Health Care Improvement. This recommendation, however, is not an evidence-based one. METHODS A systematic review on the benefits and disadvantages of semi-upright position in ventilated patients w...
متن کاملEffect of body position and head of bed angle on intra-abdominal and endotracheal tube cuff pressure in mechanically ventilated patients
Introduction: Changing position is one of the typical nursing care in intensive care units. This study aimed to investigate the effect of body positioning on intra-abdominal pressure and endotracheal tube cuff pressure and their relationship with each other in patients undergoing mechanical ventilation Materials and Methods: This was a before-after clinical trial study performed on 70 patients ...
متن کاملCan the Flutter Valve improve respiratory mechanics and sputum production in mechanically ventilated patients? A randomized crossover trial.
OBJECTIVE The Flutter Valve (Varioraw SARL, Scandipharm Inc, Birmingham, AL) has proven efficacy in hypersecretive spontaneously ventilated patients. This study was designed to evaluate whether an airway clearance protocol using the Flutter Valve can affect the therapeutic and physiologic outcomes in mechanically ventilated patients with pulmonary infection. METHODS In a randomized crossover ...
متن کاملBronchodilator delivery with metered-dose inhalers in mechanically-ventilated patients.
Metered-dose inhalers (MDIs) provide several advantages over nebulizers, including ease of administration, decreased cost, reliability of dosing, and freedom from contamination. However, this method of aerosol delivery has been considered ineffective in mechanically-ventilated patients because most of the aerosol deposits in the endotracheal tube and ventilator circuit. A smaller amount of aero...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of respiratory and critical care medicine
دوره 161 4 Pt 1 شماره
صفحات -
تاریخ انتشار 2000