Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes

نویسندگان

  • Lora Dukić
  • Ana-Maria Šimundić
  • Davorin Malogorski
چکیده

INTRODUCTION Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. MATERIALS AND METHODS Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. RESULTS Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. CONCLUSION Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of serum volume and time of exposure to gel barrier tubes on results for progesterone by Roche Diagnostics Elecsys 2010.

To the Editor: Inert thixotropic gel is commonly used in blood collection tubes for separation of serum or plasma from the cellular components of blood. Eichhorn et al. (1 ) in 1997 suggested that gel tubes (Sarstedt) used in their laboratory were generally reliable, but they found incomplete separation in 3.1% of tubes. Plain tubes are preferred for therapeutic drug monitoring because of the p...

متن کامل

Effects of storage times and temperatures on T3, T4, LH, prolactin, insulin, cortisol and progesterone concentrations in blood samples from cows.

Little is known about stability of hormones in blood samples stored under various conditions. This study was conducted to examine stability of triiodothyronine (T3), thyroxine (T4), luteinizing hormone (LH), prolactin, insulin, cortisol and progesterone in blood and serum samples. Experiment 1 was designed to determine if concentrations of these hormones were affected by exposure to cellular el...

متن کامل

Blood Collection Tubes and Storage Temperature Should Be Evaluated when Using the Siemens ADVIA Centaur XP for Measuring 25-Hydroxyvitamin D

A significant bias was found when using the Siemens ADVIA Centaur XP system for measurement of 25-hydroxyvitamin D (25OHD) with VACUETTE® tubes with Serum Clot Activator and Gel. Here, we examined whether other commonly used tubes or temperatures affected 25OHD results obtained with the Siemens ADVIA Centaur XP system. Serum was collected into five types of vacuum blood collection tubes from th...

متن کامل

Equimolar ammonia interference in potassium measurement on the Osmetech OPTI CCA: a reply.

gate collection tubes from various manufacturers, available evidence, including our data, indicates that these problems may be common. The more rapid coagulation process in clot-activator tubes may be associated with more extensive proteolysis in the specimen, potentially leading to greater protein fragmentation that is subsequently detected by mass spectrometry. Nonbiological changes, observed...

متن کامل

New geometry for TCP: severe plastic deformation of tubes

Since tubes are widely used for different industrial applications, processing of tubes by the Severe Plastic Deformation (SPD) method has been the target of different attempts. Among these attempts, development of SPD processes for tubes based on Equal Channel Angular Pressing (ECAP) has been more successful. As an illustration, Tube Channel Pressing (TCP) has been presented as an attractive SP...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2014