Quantitative myocardial blush grade for the detection of cardiac allograft vasculopathy.

نویسندگان

  • Grigorios Korosoglou
  • Nina Riedle
  • Markus Erbacher
  • Thomas J Dengler
  • Christian Zugck
  • Wolfgang Rottbauer
  • Stefan Hardt
  • Raffi Bekeredjian
  • Arnt Kristen
  • Evangelos Giannitsis
  • Neal F Osman
  • Hartmut Dickhaus
  • Hugo A Katus
چکیده

BACKGROUND Cardiac allograft vasculopathy (CAV) progressively compromises microvascular perfusion and function in heart transplantation (HTx)-recipients. The aim of our study was to investigate the ability of quantitative myocardial blush grade (MBG) to detect CAV. METHODS In consecutive HTx-recipients (n = 72) who underwent surveillance cardiac catheterization, MBG was assessed visually and quantitatively, by analyzing the time course of contrast agent intensity rise. Hereby, the parameter G(max)/T(max) was calculated as the plateau of grey-level intensity (G(max)) divided by the time-to-peak intensity (T(max)). HTx-recipients and 18 healthy volunteers underwent cardiac magnetic resonance, to assess diastolic strain rates and myocardial perfusion reserve during pharmacologic hyperemia. RESULTS Significant correlations were observed between G(max)/T(max) with perfusion reserve and with mean diastolic strain rates (r(2) = 0.68 and r(2) = 0.58, P < .001 for both). Visual and quantitative MBG using a cutoff value of G(max)/T(max) = 2.7/s yielded significantly higher accuracy than stenosis severity on coronary angiograms for the detection of impaired microvascular integrity as a surrogate marker for CAV (AUC = 0.78, SE = 0.06, 95% CI = 0.66-0.87 for lumen narrowing versus AUC = 0.91, SE = 0.03, 95%CI = 0.84-0.97 for G(max)/T(max); P < .01). Furthermore, quantitative MBG provided more robust prediction of survival (chi(2)= 14.0, P < .001), compared to visually estimated blush (chi(2)= 5.4, P = .02) and to coronary lumen narrowing assessment, (chi(2)= 4.8, P = .04). CONCLUSIONS Quantification of MBG can be performed on coronary angiograms of HTx-recipients, and may help with the identification of early CAV in patients with impaired perfusion reserve but without angiographically evident atherosclerosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic Resonance for Noninvasive Detection of Microcirculatory Disease Associated With Allograft Vasculopathy: Intracoronary Measurement Validation.

INTRODUCTION AND OBJECTIVES Cardiac allograft vasculopathy affects both epicardial and microcirculatory coronary compartments. Magnetic resonance perfusion imaging has been proposed as a useful tool to assess microcirculation mostly outside the heart transplantation setting. Instantaneous hyperemic diastolic flow velocity-pressure slope, an intracoronary physiology index, has demonstrated a bet...

متن کامل

Prevention of Cardiac Allograft Vasculopathy in Heart Transplantation

Heart transplantation is a well established therapy for end-stage heart failure. Long-term results are limited by malignancy and cardiac allograft vasculopathy. The causes for cardiac allograft vasculopathy and the predictors for its onset and progression are multifactorial and determined by both immunological and non-immunological risk factors. The detection of cardiac allograft vasculopathy i...

متن کامل

The challenge to detect heart transplant rejection and transplant vasculopathy non-invasively - a pilot study

BACKGROUND Cardiac allograft rejection and vasculopathy are the main factors limiting long-term survival after heart transplantation.In this pilot study we investigated whether non-invasive methods are beneficial to detect cardiac allograft rejection (Grade 03 R) and cardiac allograft vasculopathy. Thus we compared multi-slice computed tomography and magnetic resonance imaging with invasive met...

متن کامل

Resting echocardiography and quantitative dipyridamole technetium-99m sestamibi tomography in the identification of cardiac allograft vasculopathy and the prediction of long-term prognosis after heart transplantation.

AIMS To evaluate the accuracy of echocardiography in conjunction with quantitative high-dose dipyridamole technetium-99m sestamibi tomography (SPECT) in detecting coronary allograft vasculopathy. METHODS AND RESULTS Seventy-eight consecutive heart transplant recipients underwent echocardiography while at rest and high-dose dipyridamole SPECT within 48 h of a yearly angiogram. Resting wall mot...

متن کامل

Intracoronary ultrasound assessment of morphological and functional abnormalities associated with cardiac allograft vasculopathy.

BACKGROUND The diffuse nature of cardiac allograft vasculopathy makes early detection of the disease by traditional noninvasive methods or coronary angiography difficult. The aim of this study was to determine if there is a relation between abnormalities in vessel wall morphology, as assessed by intracoronary ultrasound, and a decreased vasodilatory response to the endothelium-dependent vasodil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American heart journal

دوره 159 4  شماره 

صفحات  -

تاریخ انتشار 2010