Boron doped diamond and glassy carbon electrodes comparative study of the oxidation behaviour of cysteine and methionine.

نویسندگان

  • T A Enache
  • A M Oliveira-Brett
چکیده

The electrochemical oxidation behaviour at boron doped diamond and glassy carbon electrodes of the sulphur-containing amino acids cysteine and methionine, using cyclic and differential pulse voltammetry over a wide pH range, was compared. The oxidation reactions of these amino acids are irreversible, diffusion-controlled pH dependent processes, and occur in a complex cascade mechanism. The amino acid cysteine undergoes similar three consecutive oxidation reactions at both electrodes. The first step involves the oxidation of the sulfhydryl group with radical formation, that undergoes nucleophilic attack by water to give an intermediate species that is oxidized in the second step to cysteic acid. The oxidation of the sulfhydryl group leads to a disulfide bridge between two similar cysteine moieties forming cysteine. The subsequent oxidation of cystine occurs at a higher potential, due to the strong disulfide bridge covalent bond. The electro-oxidation of methionine at a glassy carbon electrode occurs in two steps, corresponding to the formation of sulfoxide and sulfone, involving the adsorption and protonation/deprotonation of the thiol group, followed by electrochemical oxidation. Methionine undergoes a one-step oxidation reaction at boron doped diamond electrodes due to the negligible adsorption, and the oxidation also leads to the formation of methionine sulfone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peptide methionine sulfoxide reductase A (MsrA): direct electrochemical oxidation on carbon electrodes.

The direct electrochemical behaviour of peptide methionine sulfoxide reductase A (MsrA) adsorbed on glassy carbon and boron doped diamond electrodes surface, was studied over a wide pH range by cyclic and differential pulse voltammetry. MsrA oxidation mechanism occurs in three consecutive, pH dependent steps, corresponding to the oxidation of tyrosine, tryptophan and histidine amino acid residu...

متن کامل

Electrochemical oxidation of oxalic acid at highly boron-doped diamond electrodes.

Electrochemical oxidation of oxalic acid has been investigated at bare, highly boron-doped diamond electrodes. Cyclic voltammetry and flow injection analysis with amperometric detection were used to study the electrochemical reaction. Hydrogen-terminated diamonds exhibited well-defined peaks of oxalic acid oxidation in a wide pH range. A good linear response was observed for a concentration ran...

متن کامل

Electrochemical oxidation of chlorophenols at a boron-doped diamond electrode and their determination by high-performance liquid chromatography with amperometric detection.

Anodically pretreated diamond electrodes have been used for the detection of chlorophenols (CPs) in environmental water samples after high-performance liquid chromatographic (HPLC) separation. The anodization of as-deposited boron-doped polycrystalline diamond thin-film electrodes has enabled the stable determination of phenols over a wide concentration range. Prior to the HPLC analysis, a comp...

متن کامل

Electrochemical behavior of triflusal, aspirin and their metabolites at glassy carbon and boron doped diamond electrodes.

The electrochemical behavior of triflusal (TRF) and aspirin (ASA), before and after hydrolysis in water and in alkaline medium using two different electrode surfaces, glassy carbon and boron doped diamond, was study by differential pulse voltammetry over a wide pH range. The hydrolysis products are 2-(hydroxyl)-4-(trifluoromethyl)-benzoic acid (HTB) for triflusal and salicylic acid (SA) for asp...

متن کامل

Studies on Novel Flow - Based Electrochemical Methods for Trace and Ultratrace Analysis of Some Harmful Substances

55 This works describes the development of novel flow-based electrochemical methods and their application to the determination of some harmful substances: antibiotics (lincomycin, chloramphenicol), antibacterial agents (sulfonamides), and heavy metals (lead, cadmium and zinc), in pharmaceuticals, foods, and drinking water. The electroanalysis of lincomycin was investigated using boron-doped dia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bioelectrochemistry

دوره 81 1  شماره 

صفحات  -

تاریخ انتشار 2011