A novel vascular sealing device for closure of percutaneous arterial access sites.
نویسندگان
چکیده
The purpose of this study was to investigate the safety and efficacy of a novel vascular sealing device that incorporates a unique low-profile balloon-positioning catheter and a procoagulant delivered after diagnostic cardiac catheterization and percutaneous transluminal coronary angioplasty (PTCA) procedures. Current management of the vascular access site after percutaneous interventions is associated with patient discomfort and complications. Based on previously reported successful results in canine models, we proceeded with this first human feasibility and safety study. Immediately after an invasive procedure, the sealing device was successfully deployed at the femoral arterial access site in 24 of 24 procedures (diagnostic 19, PTCA 5). All patients were followed up at 1 month with clinical assessment, ankle-brachial index measurement, and Doppler ultrasound. Successful hemostasis was achieved in all patients. The activated clotting time before sealing device deployment was 125.5 +/- 22.2 and 267.8 +/- 60.0 seconds for diagnostic and PTCA patients, respectively. The time to hemostasis was 2.5 +/- 0.9 minutes for diagnostic and 6.0 +/- 2.2 minutes for PTCA patients. No major complications were observed. Coagulation markers (fibrinogen, D-dimer, thrombin-antithrombin-3 complex, and prothrombin fragment 1 and 2) measured before and after sealing device deployment did not reveal excessive intravascular thrombin generation or other coagulopathy. This novel vascular sealing device successfully achieves safe and effective vascular access site hemostasis immediately after cardiac catheterization and PTCA. These promising first human results will need to be confirmed by a multicenter randomized trial.
منابع مشابه
Vascular Healing After Arterial Access : A Histopathological Comparison of Standard Seldinger Versus a Novel Access Technology
With the introduction of percutaneous arterial access by Seldinger in 1953, the need for surgical arteriotomy was eliminated.1 However, potential trauma to the artery from needle puncture, the introduction of multiple catheters, and the process of closure was recognized early and has, to some degree, remained unresolved for 60 years. Manual compression is generally effective for closure, but it...
متن کاملArterial access-site complications after use of a vascular closure device related to puncture height
BACKGROUND To analyze differences of access-site complications related to the height of femoral arterial puncture and the use of a vascular closure device (VCD) following percutaneous coronary intervention (PCI). METHODS A subgroup of the FERARI study being treated by femoral arterial access and valuable inguinal angiography before implantation of a VCD were included. Inguinal angiographies w...
متن کاملSafety and Efficacy of the Prostar XL Vascular Closing Device for Percutaneous Closure of Large Arterial Access Sites
Purpose. The purpose of this study is to retrospectively evaluate the efficacy and safety of the Prostar XL device for percutaneous large access site closure in an unselected patient and operator collective. Materials and Methods. All patients (n = 50) who had received percutaneous vascular closing with the Prostar XL device in our institution with follow-up data of at least 6 months were retro...
متن کاملPercutaneous Treatment of Iatrogenic Femoral Artery Access Complications
Percutaneous minimal invasive treatment of iatrogenic femoral artery access complications (IFAACs) is considered as a first choice treatment in selected cases. Percutaneous procedures are performed under local anaesthesia, are better tolerated by the patient, and are associated with a shorter hospitalisation time, compared to open surgery. Bleeding complications can be insidious and life-threat...
متن کاملThe use of percutaneous suture-mediated closure for the management of 14 French femoral venous access.
BACKGROUND Little has been reported regarding the utility or outcomes of femoral venous vascular closure using arterial suture closure devices. We describe results using a pre-closure approach with a 6 French (Fr) Perclose Closer S device in patients who underwent antegrade aortic valvuloplasty using 14 Fr percutaneous femoral venous access catheters. METHODS Forty-five patients underwent ant...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The American journal of cardiology
دوره 83 8 شماره
صفحات -
تاریخ انتشار 1999