Measuring cardiac changes using electrical impedance during delayed cord clamping: a feasibility trial
نویسندگان
چکیده
BACKGROUND To date no study has attempted to continuously evaluate changes in hemodynamics during delayed cord clamping in humans. We aimed to demonstrate 1. the feasibility of measurements of hemodynamics during delayed cord clamping and 2. to describe the changes that occur over each minute. RESULTS After vaginal delivery, term infants (37(0)-41(6) weeks) were placed on a Life Start® bed 10-20 cm below the placenta. Transcutaneous sensors were placed on the neck and chest to determine heart rate, stroke volume and cardiac output at each beat. Once a signal was obtained, first 5 values (taken every beat) were averaged and the percent change for each subject from baseline was calculated. 20 infants were enrolled and all had a reliable signal obtained from transcutaneous sensors and had a delay in cord clamping for about 5 minutes. Cardiac output increased from 2 to 5 minutes of life (p = 0.008). For every minute of life the cord was kept unclamped, the stroke volume increased 13.1% ± 12.3 (p = 0.0001) and cardiac output increased 12.6% ± 6.3 from baseline (p < 0.0001). While the majority of infants continued to have an increase in cardiac output at 5 minutes of life, 7/20 infants reached their peak cardiac output at 188 ± 41 seconds of life. CONCLUSIONS This study demonstrates that hemodynamic measures could be successfully obtained during the first five minutes of birth and while a newborn was receiving delayed cord clamping. This study also provides reference values for changes in cardiac output and stroke volume in well term infants during delayed cord clamping. TRIAL REGISTRATION Clinical Trials.gov NCT02195037 Registered 17 July 2014.
منابع مشابه
Umbilical Cord Clamping Timing in Preterm Infants Delivered by Cesarean Section
Background: The timing of umbilical cord clamping may affect the need to bloodtransfusion and other morbidities of preterm infants. This study aimed to compare three different cord clamping timing (immediate cord clamping, delayed cord clamping and umbilical cord milking) in preterm infants delivered by cesarean section (CS). <em...
متن کاملIs "Delayed Umbilical Cord Clamping" Beneficial for Premature Newborns?
Background: The appropriate moment for clamping the umbilical cord is controversial. Immediate cord clamping (ICC) is an item of active management of the third stage of labor (AMTSL). Unclamped umbilical cord may cause inconvenience in preterm neonates because they commonly need some levels of emergent services. Some studies revealed delayed cord clamping (DCC) of preterm neonates results in be...
متن کاملEffect of Delayed Cord Clamping on Hematocrit, and Thermal and Hemodynamic Stability in Preterm Neonates: A Randomized Controlled Trial.
OBJECTIVE To evaluate the short term clinical effects of delayed cord clamping in preterm neonates. DESIGN Randomized controlled trial. SETTING A tertiary care neonatal unit from October 2013 to September 2014. PARTICIPANTS 78 mothers with preterm labor between 27 to 316/7 weeks gestation. INTERVENTION Early cord clamping (10 s), delayed cord clamping (60 s) or delayed cord clamping (60...
متن کاملEffect of timing of umbilical cord clamping on anaemia at 8 and 12 months and later neurodevelopment in late pre-term and term infants; a facility-based, randomized-controlled trial in Nepal.
BACKGROUND Delayed cord clamping at birth has shown to benefit neonates with increased placental transfusion leading to higher haemoglobin concentrations, additional iron stores and less anaemia later in infancy, higher red blood cell flow to vital organs and better cardiopulmonary adaptation. As iron deficiency in infants even without anaemia has been associated with impaired development, dela...
متن کاملInstantaneous measurement of left and right ventricular stroke volume and pressure-volume relationships with an impedance catheter.
The feasibility of using continuous on-line recording of intraventricular electrical impedance to measure ventricular stroke volume was assessed in 12 patients at cardiac catheterization with a multielectrode impedance catheter and a 1.3 kHz measuring current of 4 microA. Stroke volumes determined by electrical impedance were compared with stroke volumes determined by the thermodilution techniq...