New PointFocusing Monochromator
نویسندگان
چکیده
منابع مشابه
X-ray multilayer monochromator with enhanced performance.
An x-ray multilayer monochromator with improved resolution and a low specular background is presented. The monochromator consists of a lamellar multilayer amplitude grating with appropriate parameters used at the zeroth diffraction order. The device is fabricated by means of combining deposition of thin films on a nanometer scale, UV lithography, and reactive ion etching. The performance of thi...
متن کاملIn-focus monochromator: theory and experiment of a new grazing incidence mounting.
UNLABELLED A varied-space grating mounted to both rotate and translate constitutes a practical single element fixed slit monochromator which is in focus at all wavelengths. KEYWORDS Monochromators, diffraction gratings, grazing incidence, x-ray optics.
متن کاملA soft X-ray plane-grating monochromator optimized for elliptical dipole radiation from modern sources
A new but yet well proven way of making elliptically polarized dipole radiation from the BESSY II storage ring applicable to the SX700-type collimated plane-grating monochromator PM3 is described. It is shown that due to the limited vertical acceptance of the grating a simple use of vertical apertures is not possible in this case. Rather, deflecting the beam upwards or downwards by rotating the...
متن کاملA diffracted-beam monochromator for long linear detectors in X-ray diffractometers with Bragg-Brentano parafocusing geometry.
A new diffracted-beam monochromator has been developed for Bragg-Brentano X-ray diffractometers equipped with a linear detector. The monochromator consists of a cone-shaped graphite highly oriented pyrolytic graphite crystal oriented out of the equatorial plane such that the parafocusing geometry is preserved over the whole opening angle of the linear detector. In our standard setup a maximum w...
متن کاملCalibration of a monochromator using a lambdameter
The standard procedure for wavelength calibration of monochromators in the visible and near infrared wavelength range uses low-pressure gas discharge lamps with spectrally well-known emission lines as primary wavelength standard. The calibration of a monochromator in the wavelength range of 350 to 2500 nm usually takes some days due to the huge number of single measurements necessary. The useab...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -