Measurement of myocardial blood volume and water exchange using ferumoxytol
نویسندگان
چکیده
Background Accurate, quantitative mapping of myocardial blood volume (MBV) could potentially serve as a novel biomarker for cardiovascular disease. However, quantitative measurement of MBV can be technically difficult. Typical gadolinium based contrast agents leak out of the vasculature and are more suited towards measuring extracellular volume than MBV. Even with a completely intravascular contrast agent, water exchange between the intraand extravascular comparments has been shown to introduce error into MBV measurements. The Hazlewood two comparment model has been used to describe water exchange effects, and Donahue et al adapted this model to quantify the error water exchange introduces into blood volume measurements. Here we use ferumoxytol, a wholly intravascular iron based contrast agent, to characterize water exchange and quantify blood volume in a group of healthy volunteers.
منابع مشابه
A protocol for the measurement of myocardial blood volume and water exchange
Background Organ perfusion can be quantified by direct calibration of relative perfusion images using absolute blood volume (ml/100g) [1]. It is well known that for an intravascular gadolinium-based T1 shortening contrast agent, the parenchymal T1 change reflects tissue blood volume [2].However, to accurately quantify blood flow from blood volume, we must describe the compartmentalization effec...
متن کاملMeasurement of the intracellular lifetime of water to estimate myocardial cell size is not feasible in humans using clinical contrast agent doses at 1.5T
Background Measurement of the myocardial extracellular volume fraction (ECV) assumes a dynamic equilibrium with rapid exchange of an extracellular contrast agent between myocardium and blood. This equilibrium would be manifested by a linear relationship between 1/T1 (R1) of myocardium and 1/T1* (R1*) of blood. This relationship has been shown to be non-linear for high R1 values in mice, and thi...
متن کاملOptimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement
Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...
متن کاملPotential Uses of Ferumoxytol in the Magnetic Resonance Imaging of Epilepsy
Ferumoxytol (Feraheme ®) is an iron oxide nanoparticle approved by the Food and Drug Administration (FDA) in 2009 for treating anemia, but has found excellent off-label uses as contrast agent in the magnetic resonance imaging (MRI) of many neurological disorders, in particular multiple sclerosis [1], brain tumor [2], and stroke [3]. These MRI studies take advantage that ferumoxytol remains main...
متن کاملAcute effects of ferumoxytol on regulation of renal hemodynamics and oxygenation
The superparamagnetic iron oxide nanoparticle ferumoxytol is increasingly used as intravascular contrast agent in magnetic resonance imaging (MRI). This study details the impact of ferumoxytol on regulation of renal hemodynamics and oxygenation. In 10 anesthetized rats, a single intravenous injection of isotonic saline (used as volume control) was followed by three consecutive injections of fer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2015