Heat resistance and mechanism of heat inactivation in thermophilic campylobacters.

نویسندگان

  • Hong T T Nguyen
  • Janet E L Corry
  • Christopher A Miles
چکیده

The heat resistance of Campylobacter jejuni strains AR6 and L51 and the heat resistance of Campylobacter coli strains DR4 and L6 were measured over the temperature range from 50 to 60 degrees C by two methods. Isothermal measurements yielded D55 values in the range from 4.6 to 6.6 min and z values in the range from 5.5 to 6.3 degrees C. Dynamic measurements using differential scanning calorimetry (DSC) during heating at a rate of 10 degrees C/min yielded D55 values of 2.5 min and 3.4 min and z values of 6.3 degrees C and 6.5 degrees C for AR6 and DR4, respectively. Both dynamic and isothermal methods yielded mean D55 values that were substantially greater than those reported previously (0.75 to 0.95 min). DSC analysis of each strain during heating at a rate of 10 degrees C/min yielded a complex series of overlapping endothermic peaks, which were assigned to cell wall lipids, ribosomes, and DNA. Measurement of the decline in the numbers of CFU in calorimetric samples as they were heated showed that the maximum rate of cell death occurred at 56 to 57 degrees C, which is close to the value predicted mathematically from the isothermal measurements of D and z (61 degrees C). Both estimates were very close to the peak m1 values, 60 to 62 degrees C, which were tentatively identified with unfolding of the 30S ribosome subunit, showing that cell death in C. jejuni and C. coli coincided with unfolding of the most thermally labile regions of the ribosome. Other measurements indicated that several essential proteins, including the alpha and beta subunits of RNA polymerase, might also unfold at the same time and contribute to cell death.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Male-specific coliphages as indicators of thermal inactivation of pathogens in biosolids.

Male-specific (F+) coliphages have been proposed as a candidate indicator of fecal contamination and of virus reduction in waste treatment. However, in this and earlier work with a laboratory thermophilic anaerobic digester, a heat-resistant fraction of F+ coliphage populations indigenous to municipal wastewater and sludge was evident. We therefore isolated coliphages from municipal wastewater ...

متن کامل

The epidemiology of antibiotic resistance in Campylobacter.

Antibiotic resistance, particularly with the fluoroquinolones and macrolide antibiotics, has now emerged globally with thermophilic campylobacters, including Campylobacter jejuni and C. coli, giving rise to concerns about how these organisms have acquired such resistance characteristics, as well as consequences for human and animal treatment. This review examines (i) the clinical epidemiology o...

متن کامل

Determination of Bio-Oxidation Energy Released by Thermophiles in Secondary and Mixed Bio-Solids

Reaction constants and heat release during thermophilic aerobic digestion of typical secondary and mixed sludges were determined. Maximum reaction constant, determined by measuring the amounts of biodegradable volatile suspended solids (bVSS) removed, occurred in the temperature range of 55-60 ºC. Measurement of heat releases were carried out, at the same range, by the aid of a temperature ...

متن کامل

Occurrence of virulence genes and strain diversity of thermophilic campylobacters isolated from cattle and sheep faecal samples

The objective of this study was to investigate the genotypic characteristics of Campylobacter isolates in Shiraz, Iran. A total of 40 Campylobacter isolates including 20 C. jejuni and 20 C. coli were recovered from both cattle and sheep faeces by cultivation methods. The isolates were identified on the basis of polymerase chain reaction (PCR) detection of 16SrRNA and multiplex PCR to determine ...

متن کامل

Experimental Study for Investigating the Mechanism of Heat Transfer near the Critical Heat Flux in Nucleate Pool Boiling

Heat transfer coefficient in nucleate pool boiling near critical heat flux at least one orderhigher than the convectional heat transfer modes. In this paper, an experimental setup isdesigned and fabricated to investigate the mechanism of heat transfer from boiling surface tobulk liquid near critical heat flux. The images of pool boiling near the high heat flux regionreveals that the individual ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 72 1  شماره 

صفحات  -

تاریخ انتشار 2006