Impact of final coronary flow velocity reserve on late outcome following stent implantation.

نویسندگان

  • T Nishida
  • C Di Mario
  • M J Kern
  • T J Anderson
  • I Moussa
  • R Bonan
  • T Muramatsu
  • A C Jain
  • J Suarez de Lezo
  • S Y Cho
  • I T Meredith
  • J W Moses
  • A Colombo
چکیده

Aims To assess whether coronary flow velocity reserve following stent implantation is predictive of the subsequent need of target lesion revascularization. Methods and Results The outcome was examined of 417 patients enrolled in a multicentre prospective randomized study (DESTINI), who received a successful single vessel stent implantation in native coronary arteries and in whom coronary flow velocity reserve was measured. Logistic regression analysis and the receiver operator characteristic curve were used. When compared with 358 patients not requiring target lesion revascularization, 59 patients (14%) who underwent target lesion revascularization had a lower final coronary flow velocity reserve (2.33 +/- 0.87 vs 2.48+/- 0.80, P= 0.20) and smaller final minimal lumen diameter (2.62 +/- 0.66 mm vs 2.73+/- 0.60, P= 0.19); however, those differences were not statistically significant. Patients with a coronary flow velocity reserve of < 2.0 (n=109, 26%) exhibited a significantly higher target lesion revascularization rate than patients with a coronary flow velocity reserve of > or = 2.0 (22% vs 11%, P= 0.010). This difference remained significant (odds ratio=2.01, 95% CI=1.11 to 3.66) after adjustment for other variables that were also correlated with the incidence of target lesion revascularization. Conclusion The presence of a final coronary flow velocity reserve of < 2.0 is an independent predictor of the need for target lesion revascularization after stent implantation in native coronary artery lesions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of coronary flow velocity reserve using fast velocity-encoded cine MRI for noninvasive detection of restenosis after coronary stent implantation.

PURPOSE Serial change of the coronary flow velocity reserve was evaluated with fast velocity-encoded cine magnetic resonance imaging (MRI) for noninvasive detection of restenosis after coronary stent implantation. METHOD In total, 60 MRI flow studies were performed in 10 patients with coronary artery disease who undersvent elective successful stent implantation to the lesion in the proximal l...

متن کامل

Immediate and long-term effect of balloon angioplasty or stent implantation on the absolute and relative coronary blood flow velocity reserve.

BACKGROUND There is controversy regarding the immediate and long-term effects of PTCA on the coronary flow reserve. METHODS AND RESULTS A total of 54 patients with 1-vessel disease and normal left ventricular function were studied after balloon angioplasty (n=34) or stent implantation (n=20). Distal coronary blood flow velocity reserve (CFR) was defined as the ratio of adenosine-induced hyper...

متن کامل

Stent implantation alters coronary artery hemodynamics and wall shear stress during maximal vasodilation.

Coronary stents improve resting blood flow and flow reserve in the presence of stenoses, but the impact of these devices on fluid dynamics during profound vasodilation is largely unknown. We tested the hypothesis that stent implantation affects adenosine-induced alterations in coronary hemodynamics and wall shear stress in anesthetized dogs (n = 6) instrumented for measurement of left anterior ...

متن کامل

Effect of Chlamydia pneumoniae infection on coronary flow reserve and intimal hyperplasia after stent implantation in patients with angina pectoris.

OBJECTIVES Chlamydia pneumoniae (C. pneumoniae) has been detected in tissue from coronary atherosclerotic vascular lesions and may be involved in the pathogenesis of atherosclerosis. However, the effect of prior C. pneumoniae infection on coronary intimal hyperplasia after stent implantation and on coronary microvascular function is unknown. METHODS Seventy-three patients with stable angina p...

متن کامل

Coronary hemodynamics of stent implantation after suboptimal and optimal balloon angioplasty.

OBJECTIVES This study was performed to evaluate hemodynamic alterations of stent implantation after Doppler flow-guided balloon angioplasty (BA). BACKGROUND There is controversy regarding the effect of stent implantation on coronary hemodynamics after suboptimal and optimal BA. METHODS A total of 523 of 620 patients underwent Doppler-guided BA in the setting of a multicenter study and were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European heart journal

دوره 23 4  شماره 

صفحات  -

تاریخ انتشار 2002