Neutral to Earth Voltage Analysis in Harmonic Polluted Distribution Networks with Multi- Grounded Neutrals

ثبت نشده
چکیده

A multiphase harmonic load flow algorithm is developed based on backward/forward sweep to examine the effects of various factors on the neutral to earth voltage (NEV), including unsymmetrical system configuration, load unbalance and harmonic injection. The proposed algorithm composes fundamental frequency and harmonic frequencies power flows. The algorithm and the associated models are tested on IEEE 13 bus system. The magnitude of NEV is investigated under various conditions of the number of grounding rods per feeder lengths, the grounding rods resistance and the grounding resistance of the in feeding source. Additionally, the harmonic injection of nonlinear loads has been considered and its influences on NEV under different conditions are shown. Keywords—NEV, Distribution System, Multi-grounded, Backward/Forward Sweep, Harmonic Analysis

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Sitting, Sizing, and Operation of Batteries and Passive Filters to Mitigate Over-voltage and Harmonic Problems in Distribution Networks with High Photovoltaic Penetration

Photovoltaic systems (PVs), despite their many advantages, may have effects such as power quality issues (voltage and harmonics increase), short-circuits level increase, protection issues, and transient stability for network. Some of these effects are due to the high PV penetration, which encounters the network with the over-voltage and harmonics problems. In this paper, the location, size and ...

متن کامل

The Grounding of Power Systems above 600 Volts: a Practical View Point

This paper discusses grounding practices used on electric distribution systems above 600 Volts. In particular, the paper concentrates on the three-phase fourwire, multi-grounded neutral system that is extensively used in North America. The paper addresses the benefits of the multi-grounded power system and makes comparisons with other grounding system designs including ungrounded; three-wire si...

متن کامل

An Intelligent Method Based on WNN for Estimating Voltage Harmonic Waveforms of Non-monitored Sensitive Loads in Distribution Network

An intelligent method based on wavelet neural network (WNN) is presented in this study to estimate voltage harmonic distortion waveforms at a non-monitored sensitive load. Voltage harmonics are considered as the main type of waveform distortion in the power quality approach. To detect and analyze voltage harmonics, it is not economical to install power quality monitors (PQMs) at all buses. The ...

متن کامل

Characteristics Analysis of Voltage Sag and Voltage Swell in Multi-Grounded Four-Wire Power Distribution Systems

In North America, Most power distribution systems employ a four-wire multi-grounded neutral (MGN) design. This paper has explained the inherent characteristics of multi-grounded three-phase four-wire distribution systems under unbalanced situations. As a result, the mechanism of voltage swell and voltage sag in MGN feeders becomes difficult to understand. The simulation tool that has been used ...

متن کامل

A Survey on the Impact of Distributed Energy Resources on Power Flow Components

Turning to Renewable Energy Sources (RES) is the most logical politics in securing the modern society from critical changes in earth increasing temperature. However, Distributed Generation (DG) sources could lead to new challenges in electricity network, mainly allocation of DG sources in distribution level of power system will set the existing network under stress of power flow parameters. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009