Balance and knee extensibility evaluation of hemiplegic gait using an inertial body sensor network

نویسندگان

  • Yanwei Guo
  • Guoru Zhao
  • Qianqian Liu
  • Zhanyong Mei
  • Kamen Ivanov
  • Lei Wang
چکیده

BACKGROUND Most hemiplegic patients have difficulties in their balance and posture control while walking because of the asymmetrical posture and the abnormal body balance. The assessment of rehabilitation of hemiplegic gait is usually made by doctors using clinical scale, but it is difficult and could not be used frequently. It is therefore needed to quantitatively analyze the characteristics of hemiplegic gait. Thus the assessment would be simple, and real-time evaluation of rehabilitation could be carried out. METHODS Twenty subjects (ten hemiplegic patients, ten normal subjects) were recruited. The subjects walked straight for five meters at their self-selected comfortable speed towards a target line on the floor.Xsens MTx motion trackers were used for acquiring gestures of body segments to estimate knee joint angles and identify gait cycles. A practical method for data acquisition that does not need to obtain accurate distances between a knee joint and its corresponding sensors is presented. RESULTS The results showed that there were significant differences between the two groups in the three nominated angle amplitudes. The mean values of balance level of each parameter in hemiplegic gait and normal gait were: 0.21 versus 0.01, 0.18 versus 0.03, and 0.92 versus 0.03, respectively. The mean values of added angles of each parameter in hemiplegic gait and normal gait were: 74.64 versus 91.31, -76.48 versus -132.4, and 6.77 versus 35.74. CONCLUSIONS It was concluded that the wearable bio-motion acquisition platform provided a practical approach that was effective in discriminating gait symptoms between hemiplegic and asymptomatic subjects. The extensibility of hemiplegic patients' lower limbs was significantly lower than that of normal subjects, and the hemiplegic gait had worse balance level compared with normal gait. The effect of rehabilitation training of hemiplegic gait could be quantitatively analyzed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Evaluation of an Articulated Ankle Foot Orthosis with Plantarflexion Resistance on the Gait: a Case Series of 2 Patients with Hemiplegia

Ankle-foot orthoses (AFOs) have been described to have positive effects on the gait biomechanics in stroke patients. The plantarflexion resistance of an AFO is considered important for hemiplegic patients, but the evidence is still limited. The purpose of this case series was to design and evaluate the immediate effect of an articulated AFO on kinematics and kinetics of lower-limb joints in str...

متن کامل

Accuracy of Base of Support Using an Inertial Sensor Based Motion Capture System

The potential of miniature inertial sensors for human balance and gait analysis appears promising. Base of support (BOS), together with its interaction with center of mass, is a critical indicator in above mentioned research fields. This study aims to evaluate the accuracy of Xsens MVN BIOMECH, a commercial widely used inertial sensor-based motion capture system, for measuring static BOS and ex...

متن کامل

An Fes-assisted Gait Training System for Hemiplegic Stroke Patients Based on Inertial Sensors

An inertial sensor mounted on the foot of the affected body side represents an alternative to traditional foot switches in Functional Electrical Stimulation (FES)assisted gait rehabilitation systems. The inertial sensor consisting of 3 gyroscopes and 3 accelerometers can be utilised to detect gait phases which can be applied to synchronise the electrical stimulation with the gait. Additionally,...

متن کامل

Estimation of Vertical Ground Reaction Forces and Sagittal Knee Kinematics During Running Using Three Inertial Sensors

Analysis of running mechanics has traditionally been limited to a gait laboratory using either force plates or an instrumented treadmill in combination with a full-body optical motion capture system. With the introduction of inertial motion capture systems, it becomes possible to measure kinematics in any environment. However, kinetic information could not be provided with such technology. Furt...

متن کامل

Validation of an Inertial Sensor System for Quantifying Knee Function

Gait analysis has become a useful tool for clinicians in evaluating the progression of pathologies through functional analysis. The high cost and dedicated laboratories associated with the traditional camera-based motion analysis systems present the need for an alternative system. Direct measurement of kinetic parameters using inertial sensors (gyroscopes and accelerometers), in place of indire...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2013