Improvement in lesion detection with whole-body oncologic time-of-flight PET.

نویسندگان

  • Georges El Fakhri
  • Suleman Surti
  • Cathryn M Trott
  • Joshua Scheuermann
  • Joel S Karp
چکیده

UNLABELLED Time-of-flight (TOF) PET has great potential in whole-body oncologic applications, and recent work has demonstrated qualitatively in patient studies the improvement that can be achieved in lesion visibility. The aim of this work was to objectively quantify the improvement in lesion detectability that can be achieved in lung and liver lesions with whole-body (18)F-FDG TOF PET in a cohort of 100 patients as a function of body mass index, lesion location and contrast, and scanning time. METHODS One hundred patients with BMIs ranging from 16 to 45 were included in this study. Artificial 1-cm spheric lesions were imaged separately in air at variable locations of each patient's lung and liver, appropriately attenuated, and incorporated in the patient list-mode data with 4 different lesion-to-background contrast ranges. The fused studies with artificial lesion present or absent were reconstructed using a list-mode unrelaxed ordered-subsets expectation maximization with chronologically ordered subsets and a gaussian TOF kernel for TOF reconstruction. Conditions were compared on the basis of performance of a 3-channel Hotelling observer signal-to-noise ratio in detecting the presence of a sphere of unknown size on an anatomic background while modeling observer noise. RESULTS TOF PET yielded an improvement in lesion detection performance (3-channel Hotelling observer signal-to-noise ratio) over non-TOF PET of 8.3% in the liver and 15.1% in the lungs. The improvement in all lesions was 20.3%, 12.0%, 9.2%, and 7.5% for mean contrast values of 2.0:1, 3.2:1, 4.4:1, and 5.7:1, respectively. Furthermore, this improvement was 9.8% in patients with a BMI of less than 30 and 11.1% in patients with a BMI of 30 or more. Performance plateaued faster as a function of number of iterations with TOF than non-TOF. CONCLUSION Over all contrasts and body mass indexes, oncologic TOF PET yielded a significant improvement in lesion detection that was greater for lower lesion contrasts. This improvement was achieved without compromising other aspects of PET imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of time-of-flight on PET tumor detection.

UNLABELLED Time-of-flight (TOF) PET uses very fast detectors to improve localization of events along coincidence lines-of-response. This information is then utilized to improve the tomographic reconstruction. This work evaluates the effect of TOF upon an observer's performance for detecting and localizing focal warm lesions in noisy PET images. METHODS An advanced anthropomorphic lesion-detec...

متن کامل

Effect of varying number of OSEM subsets on PET lesion detectability.

UNLABELLED Iterative reconstruction has become the standard for routine clinical PET imaging. However, iterative reconstruction is computationally expensive, especially for time-of-flight (TOF) data. Block-iterative algorithms such as ordered-subsets expectation maximization (OSEM) are commonly used to accelerate the reconstruction. There is a tradeoff between the number of subsets and reconstr...

متن کامل

Impact of time-of-flight PET on whole-body oncologic studies: a human observer lesion detection and localization study.

UNLABELLED Phantom studies have shown improved lesion detection performance with time-of-flight (TOF) PET. In this study, we evaluate the benefit of fully 3-dimensional, TOF PET in clinical whole-body oncology using human observers to localize and detect lesions in realistic patient anatomic backgrounds. Our hypothesis is that with TOF imaging we achieve improved lesion detection and localizati...

متن کامل

Factors influencing the pattern and intensity of myocardial 18F-FDG uptake in oncologic PET-CT imaging

Introduction:Myocardial 18F-FDG uptake is highly variable in oncologic whole body 18F-FDG PET/CT studies, ranging from quite intense to minimal distribution. Intense or heterogeneous myocardial 18F-FDG uptake is undesirable as it may interfere with the visual or quantitative evaluation of tumoral invasion and metastases in pericardium, myocardiu...

متن کامل

First clinical experience with integrated whole-body PET/MR: comparison to PET/CT in patients with oncologic diagnoses.

UNLABELLED The recently introduced first integrated whole-body PET/MR scanner allows simultaneous acquisition of PET and MRI data in humans and, thus, may offer new opportunities, particularly regarding diagnostics in oncology. This scanner features major technologic differences from conventional PET/CT devices, including the replacement of photomultipliers with avalanche photodiodes and the ne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 52 3  شماره 

صفحات  -

تاریخ انتشار 2011