Silver(I)-selective coated-wire electrode based on an octahydroxycalix[4]arene derivative.
نویسندگان
چکیده
The performance of octahydroxycalix[4]arene derivative used as a neutral carrier for silver polymeric membrane electrode was studied. The sensor gave a good Nernstian response of 58 +/- 1 mV per decade for silver ion in the activity range 3.3 x 10(-6) to 3.3 x 10(-2) M Ag+. The limit of detection reached 2.1 x 10(-6) M Ag+ and exhibited high selectivity for silver ion against the alkali, alkaline earth and transition metal ions. The sensor can be used in wide pH range from 1.5 to 6.5. The response time of the sensor is less than 20 s. The potentiometric sensor was used as the indicator electrode in the titration of Ag+ ions by sodium chloride solution.
منابع مشابه
Al(III) Coated Wire Selective Electrode Based on 5-Bromo(salicylidene-2-aminothiophenol) Schiff Base as a New Ionophore
A new Al(III) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (PVC) matrix is coated on platinum wire to determine trace amounts of Al(III) ion in various samples. The sensor exhibits a good response for Al(III) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 M with Nernstian slope of 19...
متن کاملCoated-wire silver ion-selective electrode based on silver complex of cyclam.
A coated-wire ion-selective electrode (ISE) based on cyclam (1,4,8,11-tetraazacyclotetradecane) as a neutral carrier in a polyvinyl chloride (PVC) matrix was fabricated for the determination of Ag(I) ions. The coated-wire ISE exhibited a linear Nernstian response over the range 1 x 10(-1) to 1 x 10(-7) M with a slope of 59 +/- 2 mV per decade change and a detection limit of 5 x 10(-8) M. The IS...
متن کاملA coated wire-type lead(II) ion-selective electrode based on a phosphorylated calix[4]arene derivative.
The preparation of a lead-selective electrode based on 5,11,17,23-tetra-tert-butyl-25,26,27,28-tetrakis-(diphenylphosphinoylmethoxy)calix[4]arene (1) as an ionophore is reported. The plasticized PVC membrane containing 30% PVC, 57% ortho-nitrophenyloctylether (NPOE), 4% sodium tetraphenylborate (NaTPB) and 9% ionophore 1 was directly coated on a graphite electrode. It exhibits a nearly Nernstia...
متن کاملWire-coated silver(I) ion-selective electrode based on 2-mercaptobenzothiazole (MBT) ionophore: application to the determination of silver in real samples.
A new wire-coated silver ion-selective electrode with a wider concentration range (10(-7) M - 10(-1) M) was developed using 2-mercaptobenzothiazole (MBT) as a neutral ionophore. An optimum mixture of PVC, ionophore, dioctylphtalate (DOP) as a plasticizer and sodium tetraphenylborate (NaTPB) as an ion-pairing agent was used in preparing the coatings. The effect of various parameters, such as the...
متن کاملSelective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 19 8 شماره
صفحات -
تاریخ انتشار 2003