Efficient 3D late gadolinium enhancement imaging using the CLAWS respiratory motion control algorithm

نویسندگان

  • Jennifer Keegan
  • Permi Jhooti
  • Sonya V Babu-Narayan
  • Peter Drivas
  • Sabine Ernst
  • David N Firmin
چکیده

Background Acquisition durations of navigator gated high resolution 3D late gadolinium enhancement (LGE) studies are long (1,2). While implementation of the continuously adaptive windowing strategy (CLAWS (3)) which results in the fastest possible acquisition duration for a given breathing pattern and navigator acceptance window size may be beneficial, the respiratory-dependent and therefore, nonsmooth k-space acquisition order during gadolinium wash-out could result in increased image artifact. This study was performed to investigate if CLAWS could be used to increase the respiratory efficiency of 3D LGE imaging without detriment to image quality.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of Respiratory and Cardiac Motion from Electro-Anatomical Mapping Data for Improved Fusion of MRI to Left Ventricular Electrograms

Accurate fusion of late gadolinium enhancement magnetic resonance imaging (MRI) and electro-anatomical voltage mapping (EAM) is required to evaluate the potential of MRI to identify the substrate of ventricular tachycardia. However, both datasets are not acquired at the same cardiac phase and EAM data is corrupted with respiratory motion limiting the accuracy of current rigid fusion techniques....

متن کامل

Independent respiratory navigators for improved 3D PSIR imaging of myocardial infarctions

Introduction The distribution of viable and infarcted myocardium is typically visualized using inversion recovery (IR) late gadolinium enhancement (1) or phase-sensitive inversion recovery (PSIR) sequences (2). Transitioning PSIR from breath-hold 2D to respiratory navigator-gated 3D imaging promises higher SNR and CNR, and whole heart coverage (3,4). However, the optimal method for motion compe...

متن کامل

Relationship between Late Gadolinium Enhancement Extent in Cardiac Magnetic Resonance Imaging and Severity of Coronary Artery Disease in Old Myocardial Infarction

Purpose: To assess the relationship between the severity of coronary arteries involvement and the extent and pattern of myocardial scars in Cardiac Magnetic Resonance of patients with history of remote myocardial infarction. Materials and Methods: The Cardiac Magnetic Resonance images of sixty patients with history of remote ST segment or non-ST segment elevation myocardial infarction were ...

متن کامل

Towards cardiac and respiratory motion characterization from electrophysiology data for improved real time MR-integration

Background Electro-anatomical voltage mapping (EAM) is an invasive technique used for the identification of ventricular tachycardia (VT) substrate and subsequent guidance of VT ablation [1]. The mapping of VT substrate is very timeconsuming procedure, requires highly skilled electrophysiologist, is associated with patient risk and is an invasive procedure. Late gadolinium enhancement (LGE) MRI ...

متن کامل

‘Image-navigated 3-dimensional late gadolinium enhancement cardiovascular magnetic resonance imaging: feasibility and initial clinical results’

BACKGROUND Image-navigated 3-dimensional late gadolinium enhancement (iNAV-3D LGE) is an advanced imaging technique that allows for direct respiratory motion correction of the heart. Its feasibility in a routine clinical setting has not been validated. METHODS Twenty-three consecutive patients referred for cardiovascular magnetic resonance (CMR) examination including late gadolinium enhanceme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2013