W-band PELDOR with 1 kW microwave power: molecular geometry, flexibility and exchange coupling.

نویسندگان

  • Gunnar W Reginsson
  • Robert I Hunter
  • Paul A S Cruickshank
  • David R Bolton
  • Snorri Th Sigurdsson
  • Graham M Smith
  • Olav Schiemann
چکیده

A technique that is increasingly being used to determine the structure and conformational flexibility of biomacromolecules is Pulsed Electron-Electron Double Resonance (PELDOR or DEER), an Electron Paramagnetic Resonance (EPR) based technique. At X-band frequencies (9.5 GHz), PELDOR is capable of precisely measuring distances in the range of 1.5-8 nm between paramagnetic centres but the orientation selectivity is weak. In contrast, working at higher frequencies increases the orientation selection but usually at the expense of decreased microwave power and PELDOR modulation depth. Here it is shown that a home-built high-power pulsed W-band EPR spectrometer (HiPER) with a large instantaneous bandwidth enables one to achieve PELDOR data with a high degree of orientation selectivity and large modulation depths. We demonstrate a measurement methodology that gives a set of PELDOR time traces that yield highly constrained data sets. Simulating the resulting time traces provides a deeper insight into the conformational flexibility and exchange coupling of three bisnitroxide model systems. These measurements provide strong evidence that W-band PELDOR may prove to be an accurate and quantitative tool in assessing the relative orientations of nitroxide spin labels and to correlate those orientations to the underlying biological structure and dynamics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PELDOR at S- and X-band frequencies and the separation of exchange coupling from dipolar coupling.

A pulsed electron double resonance (PELDOR) setup working at S-band frequencies is introduced and its performance compared with an X-band setup. Furthermore, to verify experimentally that it is possible to disentangle the dipolar coupling nu(Dip) from the exchange coupling J by PELDOR we synthesized and investigated four bisnitroxide radicals. They exhibit in pairs the same distances r(AB) betw...

متن کامل

PELDOR measurements on a nitroxide-labeled Cu(II) porphyrin: orientation selection, spin-density distribution, and conformational flexibility.

Metal ions are functionally or structurally important centers in metalloproteins or RNAs, which makes them interesting targets for spectroscopic investigations. In combination with site-directed spin labeling, pulsed electron-electron double resonance (PELDOR or DEER) could be a well-suited method to characterize and localize them. Here, we report on the synthesis, full characterization, and PE...

متن کامل

Non-linear modeling, analysis, design and simulation of a solid state power amplifier based on GaN technology for Ku band microwave application

A new non-linear method for design and analysis of solid state power amplifiers is presented and applied to an aluminum gallium nitride, gallium nitride (AlGaN-GaN) high electron-mobility transistor (HEMTs) on silicon-carbide (SiC) substrate for Ku band (12.4 13.6 GHz) applications. With combining output power of 8 transistors, maximum output power of 46.3 dBm (42.6 W), PAE of 43% and linear ga...

متن کامل

A W-band pulsed ENDOR spectrometer: setup and application to transition metal centers.

The design and performance of a 95 GHz pulsed W-band EPR/ENDOR spectrometer is described with emphasis on the ENDOR part. Its unique feature is the easy and fast sample exchange at 4.2 K for frozen solution and single crystal samples. In addition, the microwave bridge power output is relatively high (maximum 267 mW), which allows the application of short microwave pulses. This increases the sen...

متن کامل

A W-band Simultaneously Matched Power and Noise Low Noise Amplifier Using CMOS 0.13µm

A complete procedure for the design of W-band low noise amplifier in MMIC technology is presented. The design is based on a simultaneously power and noise matched technique. For implementing the method, scalable bilateral transistor model parameters should be first extracted. The model is also used for transmission line utilized in the amplifier circuit. In the presented method, input/output ma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 216  شماره 

صفحات  -

تاریخ انتشار 2012