Effect of organic contamination upon microbial distributions and heterotrophic uptake in a Cape Cod, Mass., aquifer.
نویسندگان
چکیده
Bacterial abundance, distribution, and heterotrophic uptake in a freshwater aquifer contaminated by treated sewage were determined from analyses of groundwater and sediment-core samples. The number of free-living (unattached) bacteria in contaminated groundwater declined steadily with increasing distance from the source of sewage infiltration, from 1.94 (+/- 0.20) X 10(6) ml-1 at 0.21 km to 0.25 (+/- 0.02) X 10(6) ml-1 at 0.97 km. Bacterial abundance in groundwater sampled at 0.31 km correlated strongly with specific conductance and increased sharply from 4.0 (+/- 0.3) X 10(4) ml-1 at a depth of 6 m to 1.58 (+/- 0.12) X 10(6) ml-1 at 14 m, then declined at 20 and 31 m to 1.29 (+/- 0.12) X 10(6) and 0.96 (+/- 0.12) X 10(6) ml-1, respectively. A majority of the bacteria in contaminated and uncontaminated zones of the aquifer were bound to the surfaces of particulates, less than 60 micron in diameter. The glucose uptake rate, assayed at in situ and 5 microM concentrations, declined steadily in contaminated groundwater sampled along a transect. A preparative wet-sieving technique for use in processing core samples for bacterial enumeration is described and evaluated.
منابع مشابه
Potential Agents for Bioremediation of Nitrate Contamination
Addition of hydrogen or formate significantly enhanced the rate of consumption of nitrate in slurried core samples obtained from an active zone of denitrification in a nitrate-contaminated sand and gravel aquifer (Cape Cod, Mass.). Hydrogen uptake by the core material was immediate and rapid, with an apparent Km of 0.45 to 0.60 ,iM and a Vmax of 18.7 nmol cm-3 h-' at 30°C. Nine strains of hydro...
متن کاملSize-selective predation on groundwater bacteria by nanoflagellates in an organic-contaminated aquifer.
Time series incubations were conducted to provide estimates for the size selectivities and rates of protistan grazing that may be occurring in a sandy, contaminated aquifer. The experiments involved four size classes of fluorescently labeled groundwater bacteria (FLB) and 2- to 3-microns-long nanoflagellates, primarily Spumella guttula (Ehrenberg) Kent, that were isolated from contaminated aqui...
متن کاملEffect of pH, Chlorine Residual and Turbidity on the Microbial Bio Indicators of Drinking Water Network
Abstract Background and objective: Bioindicators of drinking water are always influenced by physical and chemical factors such as turbidity and chlorine. Considering the assessment of drinking water quality is based on residual chlorine, E.coli, heterotrophic bacteria and turbidity. We aimed to evaluate the effect of pH, chlorine residual and turbidity on the microbial ...
متن کاملHydrogenotrophic denitrification of drinking water using a hollow fibre membrane bioreactor
The objective of this research was to investigate the performance of a hollow fibre membrane bioreactor (HFMB) for hydrogenotrophic denitrification of contaminated drinking water. In the HFMB, H2 flows through the lumen of the hydrophobic hollow fibres and diffuses to an attached H2 oxidizing biofilm. Nitrate in the contaminated water serves as an electron acceptor. A hydrogenotrophic denitrify...
متن کاملSimulation of a Solvent Plume in a Sand and Gravel Aquifer in Cape Cod , Massachusetts Using a 3 - D Numerical Model
AND GRAVEL AQUIFER IN CAPE COD, MASSACHUSETTS USING A 3-D NUMERICAL MODEL by ALBERTO M. LAZARO B.S., Civil Engineering Cornell University, 1995 Submitted to the Department of Civil and Environmental Engineering In Partial Fulfillment of the Requirements for the Degree of MASTER OF ENGINEERING in Civil and Environmental Engineering at the MASSACHUSETTS INSTITUTE OF TECHNOLOGY June 1996 © 1996 Ma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied and environmental microbiology
دوره 48 6 شماره
صفحات -
تاریخ انتشار 1984