Deceleration-dependent left bundle branch block: a spectrum of bundle branch conduction delay.
نویسندگان
چکیده
The authors thank Dr. N.H.G. Holford, assistant professor of Medicine, Pharmacy and Pharmacological Chemistry, University of California, San Francisco, for his constructive review of this manuscript, and Dr. S. Lee, Director, Hematology Department, Cedars-Sinai Medical Center. In addition, we express our gratitude to Joye Nunn for secretarial assistance, to Lance Laforteza for graphics, and to Patricia Edwards for photography.
منابع مشابه
The fusion band in V1: a simple ECG guide to optimal resynchronization? An echocardiographic case report
BACKGROUND Patients with left bundle branch block have a preserved right bundle branch conduction and the efficacy of left ventricular pacing could be explained with the fusion between artificial pulse delivered in the left lateral wall and the spontaneous right ventricular activation. Moreover, the efficacy of left ventricular pacing could be enhanced with an optimal timing between the spontan...
متن کاملTachycardia-Dependent Left Bundle Branch Block Associated with Bradyeardia-Dependent Variable Left Bundle Branch Block
This report describes tachyeardiaand bradycardia-dependent left bundle branch block in a patient who exhibited normal intraventricular conduction with impulses intermediate in timing. During bradyeardia, longer cycles were associated with increasing degrees of incomplete left bundle branch block. These clinical observations support the existence of slow Phase 4 depolarization of latent pacemake...
متن کاملThe successful treatment of end stage of heart failure associated with complete right bundle branch block with biventricular pacemaker placement.
Biventricular pacing has been used to treat patients with symptomatic heart failure, systolic left ventricular dysfunction and intraventricular conduction delays. This modality is usually reserved for the treatment of patients with a left bundle branch block pattern on electrocardiogram. We report the successful use of biventricular pacing in a patient with heart failure and a right bundle bran...
متن کاملCatheter-induced intra-Hisian and intrafascicular block during recording of His bundle electrograms.
or even complete A-V block. Two cases are reported in which catheter-induced transient high grade Mobitz II A-V block, acute reversible prolongation of infranodal conduction time with probable intra-Hisian conduction delay, and persistent (6 hours duration) complete A-V block occurred in patients with left bundle branch block. The observations made indicate that A-V conduction times and the app...
متن کاملCatheter-Induced Intra-Hisian and Intrafascicular Block During Recording
or even complete A-V block. Two cases are reported in which catheter-induced transient high grade Mobitz II A-V block, acute reversible prolongation of infranodal conduction time with probable intra-Hisian conduction delay, and persistent (6 hours duration) complete A-V block occurred in patients with left bundle branch block. The observations made indicate that A-V conduction times and the app...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 65 5 شماره
صفحات -
تاریخ انتشار 1982