[Agreement and correlation between the frequency doubling perimetry and the blue-yellow perimetry in glaucoma: no support for selective damage].
نویسندگان
چکیده
PURPOSE To test the agreement and correlation between the frequency doubling technology and the short wavelength perimetry in glaucoma. METHODS Glaucoma patients were selected from the Glaucoma Sector of CEROF - Universidade Federal de Goiás, and then underwent frequency doubling technology and short wavelength perimetry examinations in both eyes (if eligible) on the same day in a random sequence. Pearson's correlation between the global indices (mean deviation - MD e pattern standard deviation - PSD) and the agreement between the examinations (Kappa) were obtained. RESULTS Forty-three eyes from 26 patients were included in the study. Comparing the MD (-4.5 +/- 4.5 dB for the frequency doubling technology and -8.0 +/-6.8 dB for the short wavelength perimetry, p<0.001) and PSD (6.4 +/- 2.8 dB for the FDT and 5.8 +/- 2.4 dB for SWAP, p=0.1), only MD was statistically different between the groups. The global indices MD e PSD were highly correlated between the frequency doubling technology and short wavelength perimetry (r=0.644, p<0.001 and r=0.586, p<0.001, respectively). There was a high agreement between the examinations (Kappa=0.319, p<0.001). CONCLUSION In the present study, a high correlation between the global indices (MD and PSD) by the frequency doubling technology and short wavelength perimetry was found, as well as a high agreement between the examinations. These observations indicate either that both cell populations are similarly affected by glaucomatous damage or that both methods measure activity in the same cell populations.
منابع مشابه
Comparison of Matrix Frequency-Doubling Technology (FDT) Perimetry with the SWEDISH Interactive Thresholding Algorithm (SITA) Standard Automated Perimetry (SAP) in Mild Glaucoma
This study aimed to compare second-generation frequency-doubling technology (FDT) perimetry with standard automated perimetry (SAP) in mild glaucoma. Forty-seven eyes of 47 participants who had mild visual field defect by SAP were included in this study. All participants were examined using SITA 24-2 (SITA-SAP) and matrix 24-2 (Matrix-FDT). The correlations of global indices and the number of d...
متن کاملGlaucomatous visual field damage. Luminance and color-contrast sensitivities.
Using a modified Humphrey perimeter, we evaluated 16 eyes with primary open-angle glaucoma and visual field loss (defects 0.5-3.0 log units in depth), and 14 normal eyes. Each eye was tested twice in random order with conventional luminance-increment static perimetry and with the perimeter modified to produce a high-luminance yellow adapting background and a blue test stimulus. The background w...
متن کاملTest-retest variability of frequency-doubling perimetry and conventional perimetry in glaucoma patients and normal subjects.
PURPOSE To compare the test-retest variability characteristics of frequency-doubling perimetry, a new perimetric test, with those of conventional perimetry in glaucoma patients and normal control subjects. METHODS The study sample contained 64 patients and 47 normal subjects aged 66.16+/-11.86 and 64.26+/-7.99 years (mean +/- SD), respectively. All subjects underwent frequency-doubling perime...
متن کاملComparison of visual evoked potentials, automated perimetry and frequency-doubling perimetry in early detection of glaucomatous visual field loss.
The present study compares frequency-doubling perimetry (FDP), automated perimetry (AP) and visual evoked potentials (VEP) for their ability to diagnose early glaucoma. In present study 224 patients of Clinic for Eye Diseases, Clinical Hospital "Sestre Milosrdnice" that had diagnosis of open angle glaucoma and glaucomatous visual field loss proven by automated static perimetry on only one eye w...
متن کاملDiagnostic tools for glaucoma detection and management.
Early diagnosis of glaucoma is critical to prevent permanent structural damage and irreversible vision loss. Detection of glaucoma typically relies on examination of structural damage to the optic nerve combined with measurements of visual function. To aid the clinician in evaluation of visual function and structure, computer-based devices such as confocal scanning laser ophthalmoscopy, scannin...