Seismic Displacement Demands for Hybrid Precast Concrete Shear Walls

نویسندگان

  • Brian J. Smith
  • Yahya C. Kurama
چکیده

This paper presents an analytical investigation on the peak lateral displacement demands of “hybrid” precast concrete panelized shear wall structures under seismic loading. The hybrid wall structure investigated uses a combination of mild [i.e., Grade 400 (U.S. Grade 60)] steel bars and highstrength unbonded post-tensioning (PT) strands for lateral resistance across horizontal joints. The analytical work follows from a previous experimental validation of the hybrid wall system for ACI 318 (2011) adoption as “special” reinforced concrete shear walls based on the testing of six 40%-scale precast test specimens (four solid and two perforated walls) under reversed-cyclic lateral loading (Smith et al. 2012). The broad goal of the analytical program was to accurately reproduce and predict the hysteretic behavior of the hybrid system. Upon successful validation of the analytical models based on the measured behaviors of the test specimens, nonlinear dynamic time-history analyses of a full-scale prototype structure were conducted under an exhaustive ensemble of selected ground motion records. The dynamic analysis results provide a critical link between the prescribed lateral displacements that were used in the design and validation testing of the wall specimens per ACI ITG-5.1 (2007) and the expected seismic demands from earthquake loading. Ultimately, these results further support the successful code approval of hybrid precast concrete shear walls for moderate and high seismic regions of the United States.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic Behavior of a Hybrid Precast Concrete Wall Specimen: Measured Response versus Design Predictions

This paper presents the results from the testing of a 0.4-scale “hybrid” precast concrete wall specimen under reversed-cyclic lateral loads combined with gravity loading. The specimen was designed to conform to the requirements of ACI ITG-5.2 (2009) and tested according to ACI ITG-5.1 (2007) to ultimately support the validation of hybrid precast walls for use in moderate and high seismic region...

متن کامل

Comparison of Hybrid and Emulative Precast Concrete Shear Walls for Seismic Regions

This paper compares the measured lateral load behavior of a 0.4-scale “hybrid” precast concrete wall test specimen with the behavior of a second precast specimen designed to emulate monolithic cast-in-place reinforced concrete shear walls. Both walls have the same overall geometry and are constructed by placing rectangular wall panels across horizontal joints. The lateral resistance at the join...

متن کامل

Ranking Passive Seismic Control Systems by Their Effectiveness in Reducing Responses of High-Rise Buildings with Concrete Shear Walls Using Multiple-Criteria Decision Making

In recent decades, the dual systems of steel moment-resisting frames and RC shear walls have found extensive application as lateral load-resisting systems for high-rise structures in seismically active areas. This paper investigated the effectiveness of tuned mass damper (TMD), viscous damper, friction damper, and the lead-core rubber bearing in controlling the damage and seismic response of hi...

متن کامل

Performance of the Modified Precast Beam to Column Connection Placed on a Concrete Corbel

Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...

متن کامل

Tests on Seismic Behavior of Pre-cast Shear Walls with Vertical Reinforcements Spliced by Two Different Grout Ways

To evaluate the seismic performance of pre-cast concrete shear wall with vertical reinforcements spliced by two different grout ways, quasi-static tests of two concrete shear walls holed by prefabricated corrugated pipe and one concrete shear wall holed by drawing out the pipe were tested. The test results showed that the wall holed by prefabricated corrugated pipe was basically the same as the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013