Selective potentiometric determination of uric acid with uricase immobilized on ZnO nanowires
نویسندگان
چکیده
In this study, a potentiometric uric acid biosensor was fabricated by immobilization of uricase onto zinc oxide (ZnO) nanowires. Zinc oxide nanowires with 80-150 nm in diameter and 900 nm to 1.5 μm in lengths were grown on the surface of a gold coated flexible plastic substrate. Uricase was electrostatically immobilized on the surface of well aligned ZnO nanowires resulting in a sensitive, selective, stable and reproducible uric acid biosensor. The potentiometric response of the ZnO sensor vs Ag/AgCl reference electrode was found to be linear over a relatively wide logarithmic concentration range (1 to 650 μM) suitable for human blood serum. By applying a Nafion membrane on the sensor the linear range could be extended to 1 to 1000 μM at the expense of an increased response time from 6.25 s to less than 9 s. On the other hand the membrane increased the sensor durability considerably. The sensor response was unaffected by normal concentrations of common interferents such as ascorbic acid, glucose, and urea.
منابع مشابه
A Potentiometric Indirect Uric Acid Sensor Based on ZnO Nanoflakes and Immobilized Uricase
In the present work zinc oxide nanoflakes (ZnO-NF) structures with a wall thickness around 50 to 100 nm were synthesized on a gold coated glass substrate using a low temperature hydrothermal method. The enzyme uricase was electrostatically immobilized in conjunction with Nafion membrane on the surface of well oriented ZnO-NFs, resulting in a sensitive, selective, stable and reproducible uric ac...
متن کاملHighly sensitive and selective uric acid biosensor based on direct electron transfer of hemoglobin-encapsulated chitosan-modified glassy carbon electrode.
A uric acid biosensor based on the direct electron transfer of a hemoglobin-encapsulated chitosan-modified glassy carbon electrode was developed for a highly sensitive and selective analysis in urine samples. The modified electrode was prepared by the encapsulation of hemoglobin and uricase in a chitosan matrix. The hydrogen peroxide produced from the catalytic oxidation of uric acid by uricase...
متن کاملSelective determination of urea using urease immobilized on ZnO nanowires
Well-aligned zinc oxide (ZnO) nanowire arrays were fabricated on gold-coated plastic substrates using a low-temperature aqueous chemical growth (ACG) method. The ZnO nanowire arrays with 50-130 nm diameters and ~1 μm in lengths were used in an enzymebased urea sensor through immobilization of the enzyme urease that was found to be sensitive to urea concentrations from 0.1 mM to 100 mM. Two line...
متن کاملZnO Nanorods Based Enzymatic Biosensor for Selective Determination of Penicillin
In this study, we have successfully demonstrated the fabrication of a biosensor based on well aligned single-crystal zinc oxide (ZnO) nanorods which were grown on gold coated glass substrate using a low temperature aqueous chemical growth (ACG) method. The ZnO nanorods were immobilized with penicillinase enzyme using the physical adsorption approach in combination with N-5-azido-2-nitrobenzoylo...
متن کاملImmobilized-enzyme nylon-tube reactor for routine determination of uric acid in serum.
We report here the preparation of an immobilized-enzyme nylon-tube reactor containing uricase (EC 1.7.3.3) and the assembly of a flow-through system (Technicon AutoAnalyzer II) for the routine determination of uric acid in serum. Results of these uric acid analyses by use of immobilized uricase, in conjunction with peroxidase (EC 1.11.1.7) and aminophenazone-dichlorophenol in solution, are comp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -