Virtual intra-arterial angioscopy (VIA) of the carotid artery based on helical CT data.

نویسندگان

  • N Rilinger
  • H Seifarth
  • R Sokiranski
  • S Krämer
  • F Liewald
  • J Goerich
  • A Tomzcak
  • C E E Nierhoff
چکیده

The purpose of this study was to visualize both the vessel wall and atherosclerotic plaques in virtual intra-arterial angioscopy (VIA) based on helical CT data sets. To achieve this in vitro, the optimal reconstruction threshold of the vessel wall was determined to be 56.4% of the maximum enhancement. Using this threshold, 20 patients suffering from symptomatic carotid disease were examined in a helical CT scanner. The degree of stenosis was defined using the North American Symptomatic Endarterectomy Trial (NASCET) criteria and compared with results from digital substraction angiography (DSA). Grading of stenoses was only possible by adding the separately computed plaque geometry to the geometry of the vessel wall in a second step. Correlation between VIA and DSA in low grade, medium grade and high grade stenosis was 88%, 93% and 71%, respectively. Complete occlusions were diagnosed correctly in all patients. Sensitivity and specificity for the correct diagnosis of high grade stenosis was 93.7% and 91.3%, respectively. A realistic depiction of intraluminal structures in carotid arteries can only be generated by displaying both the vessel wall and plaque structures simultaneously.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing the intima-media thickness and Young modulus changes of the common carotid artery in the neck region external radiotherapy based on the processing of ultrasonic images

Since it is too vital to the prevention of carotid disease in the vascular system, it seems necessary to the estimation of the elastic behavior of the carotid artery in head and neck external radiotherapy. In the present study, a total of 24 neck carcinoma patients treated with external radiotherapy had been studied. The carotid mean dose values were determined for each case by contouring the c...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

Prevalence of carotid arterial diseases in patients undergoing CABG operations

 Introduction: Prevalence of stroke following coronary artery bypass graft surgery (CABG) is % 2.1-5.2 and associated with high mortality. The purpose of this study was to investigate the prevalence of carotid artery disease in patients undergoing CABG surgery.  Methods: This cross-sectional study was performed in the years 2010-2011 on 192 patients who underwent open heart surgery (CABG) in...

متن کامل

Kinematics parameter extraction of longitudinal movement of common carotid arterial wall in healthy and atherosclerotic subjects based on consecutive ultrasonic image processing

Introduction:In this study, a non-invasive method based on consecutive ultrasonic image processing is introduced to assess time rate changes of the carotid artery wall displacement, velocity and acceleration in the longitudinal direction. The application of these parameters to discriminate healthy and atherosclerotic arteries was evaluated. Methods:Longitudinal displacement rate of common ...

متن کامل

Three-dimensional images by helical CT scan with intra-arterial injection of diluted contrast medium.

Eighty-seven patients with primary or metastatic brain tumors who were admitted to the National Cancer Center Hospital since April 1996, underwent a helical CT scan during cerebral angiography using the IVR-CT system (Toshiba Medical Systems, Tokyo, Japan), which comprised a digital subtraction angiography system (KXO-80C/DFP-2000A) and a helical CT scanner (X-Vision, Toshiba Medical Systems, T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of radiology

دوره 76 911  شماره 

صفحات  -

تاریخ انتشار 2003