Redox properties of several bacterial ferredoxins using square wave voltammetry.
نویسندگان
چکیده
The equilibrium reduction potential of the 2[4Fe-4S] ferredoxin (Fd) isolated from four different bacterial strains was determined at a methyl viologen-modified gold electrode using square wave voltammetry. The observed reduction potential at pH 8 for Clostridium thermoaceticum Fd was -385 mV; Clostridium pasteurianum, -393 mV; Clostridium thermosaccharolyticum, -408 mV; and Chromatium vinosum, -460 mV versus normal hydrogen electrode at 25 degrees C. The reduction potential of the C. pasteurianum Fd was found to be pH independent from pH 6.4 to 8.7, indicating that the electron transfer mechanism does not involve proton exchange. In contrast, the reduction potential of the C. thermosaccharolyticum Fd was found to be pH dependent from pH 6.4 to 8.7, with pKox approximately 7 and pKred approximately 7.5. The +30 mV change in reduction potential from pH 8.7 to 6.4 was attributed to an electrostatic interaction between the iron-sulfur cluster II and the protonated histidine 2 residue located about 6 A away. The Ch. vinosum Fd interacted reversibly at the methyl viologen-modified gold electrode, and its reduction potential was verified using visible spectroelectrochemistry. The reduction potential of Ch. vinosum Fd was found to be 30 mV more positive than previously reported. The similarities of the bacterial Fd reduction potentials are discussed in terms of the homology of their primary structure as reflected by the similarities in the visible and circular dichroic spectra.
منابع مشابه
Antioxidant Properties of Ajwain using Square wave, Cyclic voltammetry methods and DPPH method
Ajwain is one of the medicinal plants, which the highest composition is thymol, as a strong antioxidant respect to the obtained chromatograms of GC/MS. The antioxidant activity of the Ajwain is measured by square wave voltammetry method and cyclic voltammetry method and 2, 2-Diphenyl-1-picrylhydrazyl (DPPH) method in at the specific concentrations of 1%, 1.5%, 2% and 2.5% and constant pH. The r...
متن کاملProtein-film voltammetry: a theoretical study of the temperature effect using square-wave voltammetry.
Square-wave voltammetry of surface redox reactions is considered as an adequate model for a protein-film voltammetric setup. Here we develop a theoretical approach to analyze the effects of temperature on square-wave voltammograms. The performed simulations address the surface redox reactions featuring slow, modest and fast electron transfer. The theoretical calculations show that the temperatu...
متن کاملDNA Biosensor for Determination of 5-Fluorouracil based on Gold Electrode Modified with Au and Polyaniline Nanoparticles and FFT Square Wave Voltammetry
In the present study, a new biosensor for 5-Fluorouracil was described using modified goldelectrode and Fast Fourier transform square wave voltammetry (FFT SWV). Calf thymus DNAimmobilization was on a gold electrode decorated with polyaniline and gold nanoparticles. Theelectrochemical characteristics of the electrodes were investigated by cyclic voltammetry, andelectroch...
متن کاملMathcad – a Tool for Numerical Calculation of Square-wave Voltammograms
An alternative approach for numerical calculation of the square-wave voltammograms using the mathematical programming package MATHCAD is presented. A quasi-reversible redox reaction is considered and a mathematical model is developed under conditions of the square-wave voltammetry (SWV). Application of the mathematical model in MATHCAD is discussed and the file used for numerical simulation is ...
متن کاملEvaluation of the antioxidant activity of Thymus Using Electrochemical Methods and radical scavenging method
Thymus is regarded as one of the medicinal species, which according to obtained chromatograms of floral water of Thymus; one of the main components is thymol as strong antioxidant. In this study the appropriate and physically powerful correlation was found between the anti-radical and oxidation potentials. The antioxidant activity of the Thymus was measured by using square wave and cyclic volta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of biological chemistry
دوره 265 24 شماره
صفحات -
تاریخ انتشار 1990