Contrast sensitivity loss in multiple sclerosis. Selectivity by eye, orientation, and spatial frequency measured with the evoked potential.
نویسندگان
چکیده
Multiple sclerosis can produce highly selective losses in visual function. Psychophysical studies have demonstrated contrast sensitivity deficits for spatial frequencies or for stimulus orientations. Using real-time lock-in retrieval of the visual evoked potential, the authors measured contrast sensitivity in 15 cases with probable or definite multiple sclerosis and acuities of 20/40 or better. Sine-wave grating contrast threshold determinations for three spatial frequencies (1, 4, and 8 cycles/deg) and four orientations (0, 45, 90, and 135 deg) revealed contrast deficits in at least one spatial frequency and orientation in every case. In most cases the visual losses were spotty or multifocal, and not the same in both eyes. Some cases with highly selective patterns of orientation or spatial frequency losses were observed and are discussed in terms of involvement of cortical functional architecture in the disease.
منابع مشابه
Contrast sensitivity in multiple sclerosis measured by Cambridge Low Contrast Gratings: a useful clinical test?
The Cambridge Low Contrast Gratings (CLCG) were used to assess contrast sensitivity (CS) in 39 patients with clinically definite multiple sclerosis and 60 control subjects. CS was determined in both horizontal and vertical orientations and compared with visual evoked responses (VERs) in the same populations. Only 33% of patients had abnormal CS whereas 82% had abnormal VERs. There was no correl...
متن کاملOn the existence of neurones in the human visual system selectively sensitive to the orientation and size of retinal images.
1. It was found that an occipital evoked potential can be elicited in the human by moving a grating pattern without changing the mean light flux entering the eye. Prolonged viewing of a high contrast grating reduces the amplitude of the potential evoked by a low contrast grating.2. This adaptation to a grating was studied psychophysically by determining the contrast threshold before and after a...
متن کاملAssessment of Human Visual Performance with a Swept Evoked Potential Technique
A Final Report is presented for a project in visual assessment with the visual evoked response (VBR). Methods have been perfected for telling how well a person can see by direct measurement of his brain's response. Visual performance is measured in terms of contrast sensitivity and the acuity limit. The acuity limit is similar to the resolution limit measured by familiar Snellen eye charts. "Co...
متن کاملPerceptual learning of luminance contrast detection: specific for spatial frequency and retinal location but not orientation
Performance of a wide range of simple visual tasks improves with practice. Here we ask whether such learning occurs for the fundamental visual task of luminance contrast detection. In two experiments we find that contrast sensitivity increases following extensive practice at detecting briefly presented sinusoidal luminance gratings and that learning is maintained after six months. Learning is s...
متن کاملAcoustic Sensitivity of the Saccule and Daf Music
Introduction: The daf is a large Persian frame drum used as a musical instrument in both popular and classical music which can induce a percussive sound at low frequencies (146–290 Hz) with peaks of up to 130 dBspl. The percussive sounds have a power distribution in the region of saccular sensitivity. In view of the saccular stimulation by sound in humans, we decided to use cervical vestibu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 25 6 شماره
صفحات -
تاریخ انتشار 1984