Monitoring of axillary arterial pressure in a patient with Buerger's disease requiring clipping of an intracerebral aneurysm.

نویسندگان

  • O F Yacoub
  • J H Bacaling
  • M Kelly
چکیده

A 45-yr-old male with advanced Buerger's disease required surgical clipping of an intracerebral aneurysm. This case report emphasizes considerations of arterial pressure monitoring in a patient with advanced Buerger's Disease requiring a major surgical intervention.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A patient-specific study of blood flow in a cerebral aneurysm using medical images

Background: Cerebral aneurysm disease causes intracranial hemorrhage by rupturing, which can eventually, lead to organ failure or death. For this reason, it is important to anticipate the reasons for rupturing of a cerebral aneurysm from biomechanical point of view. Investigating this disease may even help the physicians to find treatments and predict the patient’s situation. This research was ...

متن کامل

EEG monitoring for induced hypotension for surgery of intracranial aneurysms.

EEG was monitored at bilateral scalp sites outside the operative field during hypotensive aneurysm surgery in 21 patients. Mean arterial blood pressure at axillary level was 50-60 mm Hg (average 55 mm) for 1.9-5.3 hours (average 3.6). Four new deficits were noted immediately post-operatively, all related to the operated site: these were attributable to intra-operative rupture with forced vascul...

متن کامل

Unruptured Middle Cerebral Artery Aneurysm in a Patient with Systemic Lupus Erthematosus: A Diagnostic Challenge

A 22-year-old female patient presented to the Emergency Department of a tertiary care hospital with symptoms of headache and nausea. She has been on a regular follow-up for the preceding three and a half years after being diagnosed as systemic lupus erythematosus (SLE). She had been treated earlier for SLE nephritis in the same institution, and had two relapses of nephrotic syndrome in the last...

متن کامل

تخمین فشار متوسط شریانی توسط پایش تهاجمی فشار شریانی با مانومتر

Background: Direct monitoring of arterial pressure using a transducer system is not affordable in most operating rooms and ICU wards in Iran. It is, however, possible to use an aneroid manometer instead, but it is not standardized yet, nor studied enough and its measurements may not be interpretable. Methods: To study the correlation of the arterial pressure readings between a manometer and a ...

متن کامل

Chronology of blood pressure changes in renal hypertension induced by solid plexiglass clips in the rat

The objective of this study was to determine the chronology of changes in blood pressure in renalhypertension induced by solid plexiglass clips in rats. Saw blades with the thickness of 0.21-0.22 mm wereused to make clips sized 4 × 2 × 2 mm from a piece of 2-mm thick plexiglass. Rats were subjected to shamoperation or left renal arterial clipping, and 1, 2, 3 and 4 weeks later blood pressure, a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 59 8  شماره 

صفحات  -

تاریخ انتشار 1987