A novel device for resistance-free biomechanical testing of the metaphysis of long bones
نویسندگان
چکیده
BACKGROUND Biomechanical testing is an essential component of bone research. In order to test the metaphyseal region of long bones, a typical location for the nowadays increasing field of osteoporotic bone changes, three-point bending and breaking test devices are suitable and widely used. The aim of our study was to increase the effectiveness of this method by using a newly developed ball-mounted platform design. This new design eliminates the negative effects of friction, present in previous studies, caused by the lengthening of the distal tibia along its diaphyseal axis while sliding over the surface of a fixed aluminum block. METHODS 70 tibiae of 35 twelve week old, female Sprague Dawley rats were separated into two groups for a metaphyseal bending/breaking test. Group 1 was made up of the rat's right tibiae, Group 2 of the left tibiae. Group 1 was tested on a solid metal block according to previously established testing devices whereas Group 2 was tested on the newly designed device: the resistance-free gliding, ball-mounted platform. Stiffness (N/mm), yield Load (N), and failure Load (N) were registered. In the evaluation of both testing procedures, the results of the right and left tibiae were compared according to the rat they originated from. RESULTS Stiffness (S) showed highly significant differences (p = 0.002) with 202.25 ± 27.010 N/mm SD (Group 1) and 184.66 ± 35.875 N/mm SD (Group 2). Yield Load (yL) showed highly significant differences (p < 0.001) with 55.31 ± 13.074 N SD (Group1) and 37.17 ± 12.464 N SD (Group2). The mean failure Load (fL) did not differ significantly (p < 0.231) between Group 1: 81.34 ± 11.972 N SD and Group 2: 79.63 ± 10.345 N SD. CONCLUSIONS We therefore conclude that, used in the three-point bending/breaking test, the mobile, ball-mounted platform device is able to efficiently eliminate the influence of friction in terms of stiffness and yield load. Failure Load was not affected. We suggest that the new ball-mounted platform device, when compared to other existing techniques, generates more accurate test results when used in the three-point bending/breaking test of the metaphysis of long bones.
منابع مشابه
Effect of Autogenous Omental Free Graft on the Biomechanical Properties of Fracture Healing in Dog
Objective- To evaluate greater omentum as an autogenous free graft in enhancing bone healing.Design- Prospective descriptive trial.Animals- Ten mongrel adult dogs, 3 to 4 years old and weighing 25.2 to 31 kg, assigned into two equal experimental and control groups (5dogs/group), were used.Procedures- Mid-shaft osteotomy on right radius was followed by a partial omentectomy in all dogs. A 30x30 ...
متن کاملPeriosteum Fracture Bone Strength THE MECHANICAL ROLE OF THE PERIOSTEUM ON THE IMPACT RESISTANCE OF BONE
Introduction: The role of periosteum in the blood supply of bones has been investigated by several investigators [5]. Its osteogenic potential, particularly its important role in fracture repair, is also well recognized [1, 3]. However, the biomechanical role of periosteum in the fracture behavior of bones has not been studied in detail. Although the periosteum is expected to be resistant to te...
متن کاملOutput-Conductance Transition-Free Method for Improving Radio-Frequency Linearity of SOI MOSFET Circuits
In this article, a novel concept is introduced to improve the radio frequency (RF) linearity of partially-depleted (PD) silicon-on-insulator (SOI) MOSFET circuits. The transition due to the non-zero body resistance (RBody) in output conductance of PD SOI devices leads to linearity degradation. A relation for RBody is defined to eliminate the transition and a method to obtain transition-free c...
متن کاملChondrodysplasia in a German Shepherd Do
Case description- A three-month-old male German Shepherd dog, with signs of instability to stand, ataxia and radiographic symptoms of chondrodysplasia is presented. The symptoms were developed since birth.Clinical Findings- On physical examination, the affected pup did not show any swelling, pain or other abnormality in the long bones by palpation, but he had ataxia in walking. Ocular examinati...
متن کاملAdded Resistance of an AUV Moving Inside a Water Pipeline Due to Wall Proximity
This paper evaluates the added resistance of a torpedo shape AUV, moving inside a water pipeline, due to wall effects within the tube. Today, there are long length pipelines of water or petroleum that need to regular inspection. Early detection of failure will help to prevent breakdown and avoid the huge cost of an accident. As pipelines are enclosed environments and difficult to access, pipeli...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2014