Reliability and criterion-related validity with a smartphone used in timed-up-and-go test

نویسندگان

  • Alejandro Galán-Mercant
  • Francisco Javier Barón-López
  • María T Labajos-Manzanares
  • Antonio I Cuesta-Vargas
چکیده

BACKGROUND The capacity to diagnosys, quantify and evaluate movement beyond the general confines of a clinical environment under effectiveness conditions may alleviate rampant strain on limited, expensive and highly specialized medical resources. An iPhone 4® mounted a three dimensional accelerometer subsystem with highly robust software applications. The present study aimed to evaluate the reliability and concurrent criterion-related validity of the accelerations with an iPhone 4® in an Extended Timed Get Up and Go test. Extended Timed Get Up and Go is a clinical test with that the patient get up from the chair and walking ten meters, turn and coming back to the chair. METHODS A repeated measure, cross-sectional, analytical study. Test-retest reliability of the kinematic measurements of the iPhone 4® compared with a standard validated laboratory device. We calculated the Coefficient of Multiple Correlation between the two sensors acceleration signal of each subject, in each sub-stage, in each of the three Extended Timed Get Up and Go test trials. To investigate statistical agreement between the two sensors we used the Bland-Altman method. RESULTS With respect to the analysis of the correlation data in the present work, the Coefficient of Multiple Correlation of the five subjects in their triplicated trials were as follows: in sub-phase Sit to Stand the ranged between r = 0.991 to 0.842; in Gait Go, r = 0.967 to 0.852; in Turn, 0.979 to 0.798; in Gait Come, 0.964 to 0.887; and in Turn to Stand to Sit, 0.992 to 0.877. All the correlations between the sensors were significant (p < 0.001). The Bland-Altman plots obtained showed a solid tendency to stay at close to zero, especially on the y and x-axes, during the five phases of the Extended Timed Get Up and Go test. CONCLUSIONS The inertial sensor mounted in the iPhone 4® is sufficiently reliable and accurate to evaluate and identify the kinematic patterns in an Extended Timed Get and Go test. While analysis and interpretation of 3D kinematics data continue to be dauntingly complex, the iPhone 4® makes the task of acquiring the data relatively inexpensive and easy to use.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and validation of an innovative tool for the assessment of biomechanical strategies: the Timed "Up and Go" - Assessment of Biomechanical Strategies (TUG-ABS) for individuals with stroke.

OBJECTIVE To develop and validate a clinical tool based on the biomechanical strategies exhibited by people with hemiparesis due to stroke during the performance of the Timed "Up and Go" test. DESIGN/METHODS The Timed "Up and Go" Assessment of Biomechanical Strategies (TUG-ABS) was developed for subjects with stroke, based on the analyses of 3 sources of information: published evidence; opini...

متن کامل

تکرارپذیری نسبی و مطلق آزمون Timed Up and Go در سالمندان ساکن اجتماع و جوانان سالم

Objectives: Relative and absolute reliability are psychometric properties of the test that many clinical decisions are based on them. In many cases, only relative reliability takes into consideration while the absolute reliability is also very important. Methods & Materials: Eleven community-dwelling older adults aged 65 years and older (69.64&plusmn;3.58) and 20 healthy young in the age ran...

متن کامل

Concurrent Validity of Functional Gait Assessment, Timed Up and Go, and Gait Speed Tests in the Persian Community-Dwelling Elderly

Objectives: The purpose of this study was to evaluate the concurrent validity of the Farsi version of Functional Gait Assessment (FGA), Timed Up & Go (TUG), and Gait Speed tests in Persian communitydwelling older adults. Methods: Subjects were 100 males in falling or no falling history group (50 subjects in each group). Subjects were community-dwelling adults aged 60-90 years who were living...

متن کامل

پایایی آزمون-بازآزمون، روایی سازه و همخوانی درونی نسخه فارسی‌شده آزمون «مقیاس تعادل پیشرفته فولرتون» در سالمندان ایرانی مقیم جامعه

Objectives: This study was performed to evaluate convergent validity, test-retest reliability and internal&nbsp;consistency of the Persian translation of the Fullerton advanced balance (FAB) for use in Iranian community-&nbsp;dwelling older adults and improve the quality of their functional balance assessment. Methods & Materials: The original scale was translated with forward-backward protoco...

متن کامل

Effect of Rocker Bar Ankle Foot Orthosis on Functional Mobility in Post-Stroke Hemiplegic Patients: Timed Up and Go and Gait Speed Assessments

Objectives: Ankle Foot Orthoses (AFOs) are widely utilized to improve walking ability in&nbsp;hemiplegic patients. The present study aimed to evaluate the effect of Rocker bar Ankle Foot&nbsp;Orthosis (RAFO) on functional mobility in post-stroke hemiplegic patients. Methods: Fifteen hemiplegic patients (men and women) who were at least 6-months poststroke&nbsp;and able to walk without an assis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2014