Proposal and analysis of a high-efficiency combined desalination and refrigeration system based on the LiBr–H2O absorption cycle—Part 2: Thermal performance analysis and discussions

نویسنده

  • Yongqing Wang
چکیده

This paper continues and concludes the study of the proposed high-efficiency combined desalination and refrigeration system based on the LiBr–H2O absorption cycle introduced in the paper that is Part 1 [Proposal and analysis of a high-efficiency combined desalination and refrigeration system based on the LiBr– H2O absorption cycle––Part 1: System configuration and mathematical model. Energy Convers Manage 2010;52:220–7], in which also the mathematical model and its validation are presented in detail. Specifically, the thermal performance of the proposed ARHP–MEE (absorption refrigeration heat pump integrated with a multi-effect evaporation desalter) system, is analyzed, and a parametric sensitivity analysis and a rough economic evaluation are carried out, to clarify and quantify the performance of this combined refrigeration and water system. Typically, driving steam with saturation pressure of 0.15– 0.35 MPa and corresponding saturation temperature of 111.4–138.9 C is applied to run the system. The combined system has good internal synergy, as demonstrated by an energy saving rate of 42% compared with the separate refrigeration-only and water-only systems in a base-case study. The refrigeration-heat cogenerated ARHP subsystem is the main reason for the synergy, with a coefficient of performance of about 1.6 and exergy efficiency above 60% when driven by 0.25 MPa saturated steam. A rough economic analysis indicates qualitatively that there is no penalty in capital equipment for an ARHP–MEE system when compared with the two single-purpose systems, and the higher energy utilization rate of the system makes the energy/operating cost lower. 2010 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proposal and analysis of a high-efficiency combined desalination and refrigeration system based on the LiBr–H2O absorption cycle—Part 1: System configuration and mathematical model

Simultaneous production of fresh water and refrigeration are often required, e.g. in warm-climate waterdeficient regions, and this study is a proposal and analysis of an efficient way of producing both of them by consuming mainly low-grade heat. After introducing the configuration choice methodology, a combined refrigeration and water system, ARHP–MEE (absorption refrigeration heat pump and mul...

متن کامل

Proposal and analysis of a high-efficiency combined desalination and refrigeration system based on the LiBr-H2O absorption cycle — Part 1: System configuration and mathematical model

Simultaneous production of fresh water and refrigeration are often required, e.g. in warm-climate water-deficient regions, and this study is a proposal and analysis of an efficient way of producing both of them by consuming mainly low-grade heat. After introducing the configuration choice methodology, a combined refrigeration and water system, ARHP-MEE (Absorption Refrigeration Heat Pump and Mu...

متن کامل

Exergy Analysis of a Novel Combined System Consisting of a Gas Turbine, an Organic Rankine Cycle and an Absorption Chiller to Produce Power, Heat and Cold

The current work investigates the exergy analysis of a new system to generate power, heat, and refrigeration. In the proposed system, the heat loss of a gas turbine (GT) is first recovered by a Heat Recovery Steam Generator (HRSD), then by an Organic Rankine Cycle (ORC) to generate warm water and additional power, respectively. In the ORC, reheating is used to increase the output power, the req...

متن کامل

Thermodynamic analysis of three combined power and refrigeration ‎Systems based on a demand

Three combined power and refrigeration system are introduced to compare and analyze for a defined demand and same fuel consumption based on thermodynamic parameters in a 24 hours period. Gas turbine and/or steam turbine are used for power generation and also ejector refrigeration cycle is used to produce cooling. These three systems are named as GER, SER and GSER. The results of three systems a...

متن کامل

Thermodynamic diagnosis of a novel solar-biomass based multi-generation system including potable water and hydrogen production

In this study, a new proposed multi-generation system as a promising integrated energy conversion system is studied, and its performance is investigated thermodynamically. The system equipped with parabolic trough collectors and biomass combustor to generate electricity, heating and cooling loads, hydrogen and potable water. A double effect absorption chiller to provide cooling demand, a proton...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010