Reverse remodeling and the risk of ventricular tachyarrhythmias in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy).
نویسندگان
چکیده
OBJECTIVES We aimed to evaluate the relationship between echocardiographic response to cardiac resynchronization therapy (CRT) and the risk of subsequent ventricular tachyarrhythmias (VTAs). BACKGROUND Current data regarding the effect of CRT on the risk of VTA are limited and conflicting. METHODS The risk of a first appropriate implantable cardioverter-defibrillator (ICD) therapy for VTA (including ventricular tachycardia, ventricular fibrillation, and ventricular flutter) was compared between high- and low-echocardiographic responders to CRT defibrillator (CRT-D) therapy (defined as ≥ 25% and <25% reductions, respectively, in left ventricular end-systolic volume [LVESV] at 1 year compared with baseline) and ICD-only patients enrolled in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy). RESULTS The cumulative probability of a first VTA at 2 years after assessment of echocardiographic response was highest among low responders to CRT-D (28%), intermediate among ICD-only patients (21%), and lowest among high responders to CRT-D (12%), with p < 0.001 for the overall difference during follow-up. Multivariate analysis showed that high responders to CRT-D experienced a significant 55% reduction in the risk of VTA compared with ICD-only patients (p < 0.001), whereas the risk of VTA was not significantly different between low responders and ICD-only patients (hazard ratio [HR]: 1.26; p = 0.21). Consistently, assessment of response to CRT-D as a continuous measure showed that incremental 10% reductions in left ventricular end-systolic volume were associated with corresponding reductions in the risk of subsequent VTA (HR: 0.80; p < 0.001), VTA/death (HR: 0.79; p < 0.001), ventricular tachycardia (HR: 0.80; p < 0.001), and ventricular fibrillation/ventricular flutter (HR: 0.75; p = 0.044). CONCLUSIONS In patients with left ventricular dysfunction enrolled in the MADIT-CRT trial, reverse remodeling was associated with a significant reduction in the risk of subsequent life-threatening VTAs. (Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy [MADIT-CRT]; NCT00180271).
منابع مشابه
Cardiac resynchronization therapy reduces left atrial volume and the risk of atrial tachyarrhythmias in MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy).
OBJECTIVES We hypothesized that reductions in left atrial volume (LAV) with a cardiac resynchronization therapy-defibrillator (CRT-D) would translate into a subsequent reduction in the risk of atrial tachyarrhythmias (AT). BACKGROUND There is limited information regarding the effect of CRT-D on the risk of AT. METHODS Percent reduction in LAV at 1 year following CRT-D implantation (pre-spec...
متن کاملHeart Failure Predictors of Response to Cardiac Resynchronization Therapy in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT)
Background—We hypothesized that combined assessment of factors that are associated with favorable reverse remodeling after cardiac resynchronization-defibrillator therapy (CRT-D) can be used to predict clinical response to the device. Methods and Results—The study population comprised 1761 patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchroniza...
متن کاملCardiac resynchronization therapy is more effective in women than in men: the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy) trial.
OBJECTIVES The purpose of this study was to investigate the factors related to sex-specific outcomes for death and heart failure events in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) trial. BACKGROUND In the MADIT-CRT trial, women seemed to achieve a better result from resynchronization therapy than men. METHODS All 1,820 pat...
متن کاملPredictors of response to cardiac resynchronization therapy in the Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (MADIT-CRT).
BACKGROUND We hypothesized that combined assessment of factors that are associated with favorable reverse remodeling after cardiac resynchronization-defibrillator therapy (CRT-D) can be used to predict clinical response to the device. METHODS AND RESULTS The study population comprised 1761 patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchroni...
متن کاملCardiac resynchronization therapy for mild heart failure: the time has come.
Current guidelines recommend cardiac resynchronization therapy (CRT), previously known as biventricular pacing, in patients with left ventricular (LV) systolic dysfunction (ejection fraction [EF] 35%), QRS prolongation ( 120 ms), and New York Heart Association (NYHA) class III or IV heart failure (HF).1 These recommendations come after multiple prospective, randomized trials demonstrated the be...