Contamination mitigation strategies for scanning transmission electron microscopy.

نویسنده

  • D R G Mitchell
چکیده

Modern scanning transmission electron microscopy (STEM) enables imaging and microanalysis at very high magnification. In the case of aberration-corrected STEM, atomic resolution is readily achieved. However, the electron fluxes used may be up to three orders of magnitude greater than those typically employed in conventional STEM. Since specimen contamination often increases with electron flux, specimen cleanliness is a critical factor in obtaining meaningful data when carrying out high magnification STEM. A range of different specimen cleaning methods have been applied to a variety of specimen types. The contamination rate has been measured quantitatively to assess the effectiveness of cleaning. The methods studied include: baking, cooling, plasma cleaning, beam showering and UV/ozone exposure. Of the methods tested, beam showering is rapid, experimentally convenient and very effective on a wide range of specimens. Oxidative plasma cleaning is also very effective and can be applied to specimens on carbon support films, albeit with some care. For electron beam-sensitive materials, cooling may be the method of choice. In most cases, preliminary removal of the bulk of the contamination by methods such as baking or plasma cleaning, followed by beam showering, where necessary, can result in a contamination-free specimen suitable for extended atomic scale imaging and analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plasma Cleaning and Its Applications for Electron Microscopy.

: The effectiveness of applying a high-frequency, low-energy, reactive gas plasma for the removal of hydrocarbon contamination from specimens and components for electron microscopy has been investigated with a variety of analytical techniques. Transmission electron microscopy (TEM) analysis of specimens that have been plasma cleaned shows an elimination of the carbonaceous contamination from th...

متن کامل

The Repeller Field debris mitigation approach for EUV sources

We describe studies of the debris produced from a high–repetition-rate laser plasma EUVL source based on the mass-limited target concept. In particular, we are developing mass-limited target designs based on complex targets containing tin. Comprehensive analysis of witness-plate detection techniques can reveal many interesting details of the interaction regime, and the impact of the debris. The...

متن کامل

Ion exchange growth of Zinc Sulfide quantum dots in aqueous solution

We report the growth by ion exchange synthesis of ZnS nanoparticles in MCM-41 matrices using Zn (CH3COO)2 and Na2S starting sources. The final product (ZnS/MCM-41) was characterized by X-ray diffraction (XRD) pattern, transmission electron microscopy (TEM), scanning electron microscopy (SEM), infrared spectrometry (IR) and UV-vis spectroscopy. Its crystalline st...

متن کامل

Ion exchange growth of Zinc Sulfide quantum dots in aqueous solution

We report the growth by ion exchange synthesis of ZnS nanoparticles in MCM-41 matrices using Zn (CH3COO)2 and Na2S starting sources. The final product (ZnS/MCM-41) was characterized by X-ray diffraction (XRD) pattern, transmission electron microscopy (TEM), scanning electron microscopy (SEM), infrared spectrometry (IR) and UV-vis spectroscopy. Its crystalline st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Micron

دوره 73  شماره 

صفحات  -

تاریخ انتشار 2015