Gradient descent algorithm applied to wavefront retrieval from through-focus images by an extreme ultraviolet microscope with partially coherent source.
نویسندگان
چکیده
The wavefront retrieval by gradient descent algorithm that is typically applied to coherent or incoherent imaging is extended to retrieve a wavefront from a series of through-focus images by partially coherent illumination. For accurate retrieval, we modeled partial coherence as well as object transmittance into the gradient descent algorithm. However, this modeling increases the computation time due to the complexity of partially coherent imaging simulation that is repeatedly used in the optimization loop. To accelerate the computation, we incorporate not only the Fourier transform but also an eigenfunction decomposition of the image. As a demonstration, the extended algorithm is applied to retrieve a field-dependent wavefront of a microscope operated at extreme ultraviolet wavelength (13.4 nm). The retrieved wavefront qualitatively matches the expected characteristics of the lens design.
منابع مشابه
Partially coherent phase microscopy with arbitrary illumination source shape
We propose a method that recovers phase from a stack of through-focus intensity images taken with a partially coherent microscope employing illumination of any arbitrary source shape. Our algorithm uses a Kalman filtering approach, which is fast, accurate and robust to noise. We validate the method in simulation and with experimental data taken on a commercial microscope with varying condenser ...
متن کاملA Note on the Descent Property Theorem for the Hybrid Conjugate Gradient Algorithm CCOMB Proposed by Andrei
In [1] (Hybrid Conjugate Gradient Algorithm for Unconstrained Optimization J. Optimization. Theory Appl. 141 (2009) 249 - 264), an efficient hybrid conjugate gradient algorithm, the CCOMB algorithm is proposed for solving unconstrained optimization problems. However, the proof of Theorem 2.1 in [1] is incorrect due to an erroneous inequality which used to indicate the descent property for the s...
متن کاملPartially coherent phase imaging with simultaneous source recovery.
We propose a new method for phase retrieval that uses partially coherent illumination created by any arbitrary source shape in Köhler geometry. Using a stack of defocused intensity images, we recover not only the phase and amplitude of the sample, but also an estimate of the unknown source shape, which describes the spatial coherence of the illumination. Our algorithm uses a Kalman filtering ap...
متن کاملAdaptive Optics Calibration for a Wide-Field Microscope
Adaptive optics calibration of a novel wide-field scanning microscope is described, comparing relevant parameters for several optimization techniques. Specifically, comparisons of the optimization algorithm, image quality metrics, and the calibration image target are detailed. It is shown that stochastic parallel gradient descent (SPGD) algorithm using image intensity as a metric provides robus...
متن کاملAdaptive optics two photon scanning laser fluorescence microscopy
Two-photon fluorescence microscopy provides a powerful tool for deep tissue imaging. However, optical aberrations from illumination beam path limit imaging depth and resolution. Adaptive Optics (AO) is found to be useful to compensate for optical aberrations and improve image resolution and contrast from two-photon excitation. We have developed an AO system relying on a MEMS Deformable Mirror (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the Optical Society of America. A, Optics, image science, and vision
دوره 31 12 شماره
صفحات -
تاریخ انتشار 2014