Computer modeling to predict effects of implant malpositioning during TKA.

نویسندگان

  • William M Mihalko
  • John L Williams
چکیده

Computer-assisted surgery has focused on alignment of implants and soft tissue balancing but the end results during surgery as they pertain to long-term function of the implants are not yet realized. One parameter that continues to be variable despite the use of computer navigation is the placement of the implants in the transverse plane. The objective of this study was to determine whether implant and anatomic registrations could be used in a computer model (LifeMOD/KneeSIM, LifeModeler, Inc., San Clemente, California) to show differences in the resulting contact patterns of the medial and lateral condyles of the polyethylene insert. The simulations included tibiofemoral and patellofemoral contact, passive soft tissue (medial and lateral collateral, and posterior cruciate ligaments, as well as the capsular tissues), and active muscle elements (quadriceps and hamstrings). Components of a fixed-bearing cruciate-retaining total knee (Columbus knee system; B. Braun Aesculap, Tuttlingen, Germany) were imported into the model. The systems were subjected to one 60-second cycle of a lunge. Both the femoral and the tibial components were positioned in 5° of internal or external rotation in varying combinations and the resulting kinematics analyzed. The resulting kinematics showed variations in anteroposterior translation of the lateral and medial femoral condyles that resembled several of those reported in the literature for individual patients with a cruciate-retaining knee implant system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computer Assisted Navigation in Knee Arthroplasty

Computer assisted surgery (CAS) was used to improve the positioning of implants during total knee arthroplasty (TKA). Most studies have reported that computer assisted navigation reduced the outliers of alignment and component malpositioning. However, additional sophisticated studies are necessary to determine if the improvement of alignment will improve long-term clinical results and increase ...

متن کامل

Evaluation of Strain Distribution in Bone around Implant in Treatment Design of Overdentures Using Computer and Modeling of Finite Elements

Introduction: Introduction: Few studies have investigated the distribution of stress around implants. In this study the distribution of stress in bones around implants was investigated in five overdenture (OD) treatment designs including OD-1, OD-2, OD-3, OD-4 and OD-5. Materials and methods: The Catia modeling software was used in order to simulate the tooth/implant model and bone. First, the ...

متن کامل

3D CAD model reconstruction of a human femur from MRI images

Medical practice and life sciences take full advantage of progress in engineering disciplines, in particular the computer assisted placement technique in hip surgery. This paper describes the three dimensional model reconstruction of human femur from MRI images. The developed program enables to obtain digital shape of 3D femur recognized by all CAD software and allows an accurate placement of t...

متن کامل

Total Knee Arthroplasty in Patients with Retention of Prior Hardware Material: What is the Outcome?

Background: There is an information gap in literature regarding postoperative outcome of total knee arthroplasty (TKA)in patients with hardware in-situ from the previous knee surgery. The present study aims to evaluate impact of retainedhardware on short-term outcome of TKA patients.Methods: Perioperative radiographs of patients who had undergone TKA between 2007 and 2012 were reviewedand patie...

متن کامل

Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy.

The purpose of this study was to build a visualization technique of the femorotibial contact in fixed-bearing total knee arthroplasty (TKA) using X-ray fluoroscopy, and to apply this technique to a TKA patient during dynamic motion. In vivo kinametcis of the metallic knee implant was determined using a 2D/3D registration technique, which uses computer assisted design (CAD) model of the implant ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Orthopedics

دوره 33 10 Suppl  شماره 

صفحات  -

تاریخ انتشار 2010