Novel Motion Correction Technique Using Orbital Navigator Echoes in Interleaved Spiral Imaging
نویسندگان
چکیده
Spiral imaging does not produce apparent flow artifacts. However, it remains sensitive to rapid rigid body motion. In this abstract, a motion correction technique using an orbital navigator “ring” in interleaved spiral imaging is presented. In this technique, a circular k-space trajectory is incorporated into each spiral interleaf. Data inconsistency due to both rotation and translation can be corrected by evaluating the magnitudes and phases of the data of the navigator “ring”. This motion correction technique is combined with an automatic field map generation method, such that no additional scanning is necessary for off-resonance correction.
منابع مشابه
High resolution, free-breathing coronary artery imaging with >99% respiratory efficiency: comparing beat to beat respiratory motion correction with navigator gating
Introduction: High-resolution coronary artery imaging is commonly gated to end-expiration using diaphragmatic navigator echoes, resulting in inherently low respiratory efficiency (RE) which is further exacerbated by respiratory drift. Recently, it was demonstrated that epicardial fat can be used as a marker of coronary artery position in a 3D beat-to-beat non-model based subject-specific respir...
متن کاملHigh resolution 3D spiral coronary vessel wall imaging with >99% respiratory efficiency using beat to beat respiratory motion correction: quantitative comparison with navigator gated 2D spiral and turbo spin echo imaging
Introduction: Dark blood coronary artery wall imaging has demonstrated the ability to detect vessel wall thickening in subjects with non-significant coronary heart disease [1]. For high resolution imaging, studies are generally performed with diaphragmatic navigator gating which has an inherently low respiratory efficiency (RE) and is further compromised by respiratory drift through the long ac...
متن کاملAutocorrection in MR imaging: adaptive motion correction without navigator echoes.
A technique for automatic retrospective correction of motion artifacts on magnetic resonance (MR) images was developed that uses only the raw (complex) data from the MR imager and requires no knowledge of patient motion during the acquisition. The algorithm was tested on coronal images of the rotator cuff in a series of 144 patients, and the improvements in image quality were similar to those a...
متن کاملHigh-resolution diffusion-weighted imaging with interleaved variable-density spiral acquisitions.
PURPOSE To develop a multishot magnetic resonance imaging (MRI) pulse sequence and reconstruction algorithm for diffusion-weighted imaging (DWI) in the brain with submillimeter in-plane resolution. MATERIALS AND METHODS A self-navigated multishot acquisition technique based on variable-density spiral k-space trajectory design was implemented on clinical MRI scanners. The image reconstruction ...
متن کاملVariable-Density Oblique Spherical Navigator Echoes to Improve Performance in Measuring 3D Motion
A. F. Costa, D. Petrie, M. Drangova Robarts Research Institute, London, Ontario, Canada, Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada Introduction: Correcting for subject motion remains a challenging problem in Magnetic Resonance Imaging. One-dimensional navigator echoes have been used successfully in a number of applications, but can only measure...