Evaluating Multipulse Integration as a Neural-Health Correlate in Human Cochlear-Implant Users

نویسندگان

  • Ning Zhou
  • Lixue Dong
چکیده

The present study evaluated the slopes of threshold-versus-pulse-rate functions (multipulse integration, MPI) in humans with cochlear implants in relation to recovery from 300-ms forward maskers. MPI has been correlated with spiral ganglion cell density in animals. The present study showed that steeper MPI functions were correlated with faster recovery from forward masking. The findings suggested that the variations in the MPI slopes are explained not only by the quantity of neurons contributing to the integration process but also by the neurons' temporal response characteristics and possibly central inhibition.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating multipulse integration as a neural-health correlate in human cochlear-implant users: Relationship to spatial selectivity.

The decrease of psychophysical detection thresholds as a function of pulse rate for a fixed-duration electrical pulse train is referred to as multipulse integration (MPI). The MPI slopes correlate with anatomical and physiological indices of cochlear health in guinea pigs with cochlear implants. The aim of the current study was to assess whether the MPI slopes were related to the spatial spread...

متن کامل

EFFECT OF A UDITORY-VERBAL REHABILITATION ON VOICE PARAMETERS IN CHILD COCHLEAR IMPLANT USERS

This study aimed to evaluate the effects of auditory-verbal rehabilitation on voice parameters after implantation with cochlear implants 2 and 5 months after rehabilitation and compare them with normal voice children (under 12 years of age). A perceptive and electroacoustic evaluation of voice was carried out through a digital analysis after implantation and rehabilitation. The study was pe...

متن کامل

The Cochlear Implant

The studies on cochlear implants have been conducted in the United States, Austria, Brasil, France, Finland, and some other countries. Up to now, this technique does not seem to have a wide spread application. Indeed it can only apply cases of deafness still presenting sufficient neural remnants to transmit the message. Moreover, the patient must be totally deaf( quasi­ complete loss of har cel...

متن کامل

Characteristics of detection thresholds and maximum comfortable loudness levels as a function of pulse rate in human cochlear implant users.

The ability of an implanted ear to integrate multiple pulses, as measured by the slopes of detection threshold level (T level) versus pulse rate functions, may reflect cochlear health in the cochlea, as suggested by previous animal studies (Kang et al., 2010; Pfingst et al., 2011). In the current study, we examined the slopes of T level versus pulse rate functions in human subjects with cochlea...

متن کامل

Evaluation of Saccular Function Pre-Post Cochlear Implant Surgery Using VEMPs

Objectives: The aim of present study was evaluation of saccule function in cochlear implant candidates with severe to profound sensory neural hearing loss Before and after cochlear implantation Methods: In this study 35 cochlear implant (CI) candidates with bilateral severe to profound sensory neural hearing loss before and about 30 days after cochlear implant and 20 normal-hearing cases as ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2016